| 数据搜索系统,热门电子元器件搜索 |
|
TARS-LCASS 数据表(PDF) 3 Page - Honeywell Solid State Electronics Center |
|
|
|||||||||||||||||||||||||||||
TARS-LCASS 数据表(HTML) 3 Page - Honeywell Solid State Electronics Center |
|
3 / 1 page ![]() Sensing and Internet of Things 3 Transportation Attitude Reference Sensor (TARS Series) Table 3. Electrical Characteristics • TARS-HCASS Catalog Listing Characteristic Min. Nominal Max. Unit Supply voltage 9 14/28 36 V Supply current – – 100 mA Reverse voltage – – -36 V Overvoltage – – 36 V Start-up time 500 – 2000 mSec Short circuit protection CAN output shorted to power line and ground Open circuit protection Single-line interruption and multiple-line interruption Reset response Automatic after voltage drop CAN output characteristics per SAE J1939 CAN Bus data rate – 250 – kBaud Signal update rate – – 100 Hz Table 4. Environmental Specifications Characteristic Parameter Operating temperature -40 °C to 85 °C [40 °F to 185 °F] Storage temperature -40 °C to 105 °C [40 °F to 221 °F] Housing PBT thermoplastic Random vibration 8 hours per axis at 16.91 g RMS per MIL-STD-202, Method 214, Test Condition I, Letter E Mechanical shock 50 g 11 mS half-sine pulse, 3 each direction, 18 total, per MIL-STD-202, Method 213 Chemical compatibility Diesel fuel, hydraulic oil, ethylene glycol, motor oil, brake fluid, urea nitrogen, liquid lime, NPK fertilizer, ammonium hydroxide, alkaline degreaser, transmission oil, power steering fluid, and axle oil Moisture resistance per MIL-STD-202, Method 106 (10 cycles, 24 hours/cycle) Thermal shock 250 cycles, -40 °C to 85 °C, 73 min dwell Salt spray 5 % salt solution, 96 hours Ingress protection IP67, IP69K (DIN40050-1993) with mating connector installed RoHS Compliant REACH Compliant UV rating Enclosure material meets outdoor suitability requirements per UL746C F1 rating Table 5. EMC Specifications Characteristic Standard Test Level, Frequency Radiated immunity ISO 11452-2 125 V/m, 400 MHz to 2.5 GHz Bulk current injection ISO 11452-4: 2011 125 mA, 1 MHz to 400 MHz Radiated emission ISO 13766 30 MHz to 1 GHz Mutual coupling ISO 7637-3 Test pulse A, Test pulse B (-80 V, 80 V) ESD direct contact discharge ISO 10605 ±8 kV ESD air discharge ISO 10605 ±15 kV |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |