| 数据搜索系统,热门电子元器件搜索 |
|
DAMMP3C3PJ 数据表(PDF) 280 Page - ITT Industries |
|
|
|||||||||||||||||||||||||||||
DAMMP3C3PJ 数据表(HTML) 280 Page - ITT Industries |
|
280 / 301 page ![]() Dimensions are shown in mm (inch) Dimensions subject to change Insulator — The insulating element into which the contacts are mounted in a connector. This can be a resilient material, thermoplastic, or a thermoset compound, among other materials. Insulator Rotation — A method of differentiating a circular connector if more than one connector with the same sex and layout is to be used in a system. The insulator is permanently positioned in the shell so that only a connector with the same degree of rotation can be mated with it. Possible rotations are specific to each layout with some layouts having many possible rotations and others having none. A chart of valid rotations is listed by layout for connectors capable of being rotated. Most connector series use the military convention of assigning letter designations for specific degrees of rotation (for example: W, X, Y, Z). See KEYING. Interchangeable — The characteristic of connectors in which a connector half of one manufacturer or series will directly replace that of another manufacturer and provide the same electrical and mechanical function. Intermateable — The characteristic of connectors in which a connector half of one manufacturer or series will mate directly with the connector half of another manufacturer. Intermittent — Occurring at intervals. A connection which passes electrical current only in random or undesirable intervals. Intermountable — The characteristic of connectors in which one manufacturer’s connector or series will mount in exactly the same panel space and mounting holes as another manufacturer’s product. ISO — Abbreviation for the International Standards Organization. A group that operates at the international level and sets most standards for industry, with the exception of electrical engineering and telecommunications which are set by the IEC and ITU respectively. CEN is the equivalent organization at the European level. Jacket — The outermost layer of insulation in a cable composed of several wires. Jackscrew — A screw attached to one half of a connector pair used to mechanically align, draw them together, and lock them in place. Key — A mechanism used to polarize connectors by the user. See KEYING. Keying — A method of differentiating a connector if more than one connector with the same sex and layout is to be used in a system. The key is usually a pin or other projection which can be located in a contact cavity or slot. The key will prevent a connector without a matching orifice from mating. Keying and POLARIZATION serve the same function, but keying can be done by the user, while polarization is manufactured into the connector and normally can not be altered by the user. Layout — The number, size, and geometric arrangement of the contacts in a connector. When a connector is said to have a certain ‘‘layout’’ it refers to a specific contact configuration. For example, Combo D has 2 pages of drawings showing the arrangement of the contacts in the insulator. Each of these contact cavity arrangements can be referred to as a layout. Locator — A part of a crimping tool TURRET. Rotation of the locator sets the tool for a particular size or sex contact. See TURRET. Male Contact — See PIN CONTACT. Mating Life — The minimum number of times a connector can be mated and unmated and still meet all of its design specifications. The maximum life may be much higher than this figure. Mil — One thousandth of an inch (.001). Used in the United States as a unit of length in wire diameters and linear dimensions. Mil-Spec — Abbreviation for Military Specification. Milliampere — One one-thousandth (.001) of an ampere. Abbreviated mA. Millimeter — Metric unit of linear measure. 1 millimeter = .03937 inches. Abbreviated mm. Milliohm — One one-thousandth (.001) of an ohm. Abbreviated m . mm2 — Millimeters squared. A standard for wire diameters used in Europe instead of AWG. As numbers get larger, wire diameters increase in size. The relationship between mm2 and AWG is reverse logarithmic. 1 mm2 =1973 circular mils. A conversion graph is needed to make accurate comparisons between AWG and mm2. Call for assistance. Mounting Clip — Any of a variety of mounting accessories used to secure a connector or connector pair to a rigid surface. Multi-Conductor Cable — Two or more individual wires surrounded by a jacketing material. Nest — The portion of a crimping die that supports the contact barrel during crimping. Newton — A unit of acceleration. One Newton is the force capable of accelerating 1 kilogram to one meter per second per second. 1 pound force = 4.448221 Newtons. Abbreviated N. Ohm — The unit of electrical resistance. One ohm is the value of resistance through which a potential difference of one volt will maintain a current of one ampere. Its symbol is the Greek letter omega ( ). Operating Temperature — The range of AMBIENT TEMPERATURES over which the connector can operate and still meet all of its design specifications. Operating Voltage — The range of voltages over which the connector can be operated. Safety precautions must be taken anytime a voltage in excess of 50V is to be used in a circuit. Check your local and national codes for guidelines. Outgassing — The circumstance in which an insulator releases gasses trapped within it under a vacuum or conditions of decreased pressure, high heat, or both. Panel — The outside surface of a piece of equipment on to which connectors are mounted. The panel is usually made of metal. Panel Mount — A connector designed to be mounted on a panel by means of screws or jam nut. PCB — Abbreviation for Printed Circuit Boards. Performance Class 1 — Performance class per European specification DIN 41652, specifying contact performance to 500 mating cycles, followed by testing per DIN 41640, Part 21. The contact is subjected to severe environmental conditions, including industrial gasses, after the 500 mating cycles, and must meet basic contact resistance, engaging force, and separation force tests. Performance Class 2 — Performance class per European specification DIN 41652, specifying contact performance to 200 mating cycles, followed by testing per DIN 41640, Part 21. The contact is subjected to severe environmental conditions, including industrial gasses, after the 200 mating cycles, and must meet basic contact resistance, engaging force, and separation force tests. D Subminiature Glossary of Terms Glossary of Terms 279 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |