-236-R
AI

The designation **"236-R"** is most commonly associated with **fixed precision resistors** or specific **thermal fuses/cutoffs**. Depending on the manufacturer, it typically refers to a component’s resistance value or a specific model number for circuit protection.
Below is a detailed breakdown of the most common electronic parts carrying the 236-R label.
---
## 1. Precision Resistors (The "R" Suffix)
In many electronic component numbering systems (like MIL-SPEC or manufacturer-specific codes), the **R** acts as a decimal point or indicates a low-resistance value.
| Parameter | Description |
| :--- | :--- |
| **Value** | 236 Ohms ($\Omega$) or 2.36 Ohms (depending on code position). |
| **Common Type** | Metal Film or Wirewound. |
| **Tolerance** | Usually $\pm 1\%$ or $\pm 0.1\%$ for precision circuits. |
| **Application** | Voltage dividers, signal conditioning, and current sensing. |
### Coding Convention Example
In the 3-digit/4-digit SMD or axial code:
* **236R**: 236 Ohms.
* **23R6**: 23.6 Ohms.
* **R236**: 0.236 Ohms.
---
## 2. Thermal Cutoffs (G4 Series / SEFUSE)
A very common part number is the **G4A00236C** (often shortened to **236-R** in repair manuals). This is a thermal fuse used to prevent appliances from overheating.
### Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Function** | One-time thermal link (non-resettable). |
| **Rated Temperature ($T_f$)** | **236°C** (The "236" denotes the cutoff temperature). |
| **Voltage Rating** | 250V AC. |
| **Current Rating** | 10A to 15A. |
| **Housing** | Ceramic or metal cylinder with axial leads. |
---
## 3. Comparison of Common "236-R" Variants
If you are looking at a physical board, use this table to identify the part:
| Appearance | Component Type | Primary Purpose |
| :--- | :--- | :--- |
| Small cylinder with colored bands | **Resistor** | Limits current flow. |
| Metal canister with two wire leads | **Thermal Fuse** | Safety cutoff at 236°C. |
| Black rectangular block (SMD) | **Precision Resistor** | Surface mount circuit logic. |
---
### How to Test the Component
If you are troubleshooting a circuit containing a 236-R part:
1. **For Resistors:** Use a Multimeter in **$\Omega$ (Ohms) mode**. It should read close to 236. If it reads "OL" (Open Loop), the resistor is blown.
2. **For Thermal Fuses:** Use **Continuity mode**.
* **Beep:** The fuse is good.
* **No Beep:** The fuse has tripped (blown) due to heat and must be replaced.
---
- ⤷How do I identify if a 236-R is a resistor or a fuse by its markings?
- ⤷ What are the risks of bypassing a 236-R thermal fuse in a circuit?
- ⤷ What is the standard tolerance for a 236-R metal film resistor?