-D4CY-R
AI

The **D4CY-R** is a specific model within the **D4CY** series of high-precision limit switches manufactured by **Omron**. These switches are designed for industrial applications requiring high repeatability, water resistance, and compact footprints.
---
### 1. Key Technical Specifications
The D4CY-R features a specialized construction designed for harsh environments. Below are its primary technical characteristics:
| Parameter | Specification |
| :--- | :--- |
| **Actuator Type** | Top Plunger (typically) |
| **Contact Form** | SPDT (Single Pole Double Throw) |
| **Rated Voltage** | 30 VDC |
| **Rated Current** | 100 mA (Resistive Load) |
| **Degree of Protection** | IP67 (Dust-tight and Water-resistant) |
| **Cable Type** | Oil-resistant Vinyl Cabtire Cable |
| **Repeatability** | High precision (±0.002 mm to ±0.005 mm depending on setup) |
---
### 2. Internal Electronic Design
Unlike standard mechanical limit switches, the D4CY-R is engineered for **low-current signaling** rather than high-power switching.
* **Gold-Clad Contacts:** The internal contacts are usually gold-plated to ensure reliable electrical conductivity even at very low voltages and currents (micro-loads). This prevents oxidation which often plagues standard silver contacts.
* **Sealing Technology:** The "R" in the series often denotes specific sealing or cable orientations. The internal switch mechanism is encased in a robust housing with an O-ring and a flexible diaphragm to prevent coolant, oil, or water ingress.
* **Wiring Configuration:** It typically utilizes a 3-wire or 4-wire configuration:
* **Common (COM):** The shared terminal.
* **Normally Closed (NC):** Circuit is closed when the plunger is at rest.
* **Normally Open (NO):** Circuit closes only when the plunger is depressed.
---
### 3. Applications
Because of its extreme precision and resistance to fluids, the D4CY-R is commonly used in:
1. **CNC Machining Centers:** For tool length offsets and position sensing where oil and coolants are present.
2. **Robotic Arms:** For precise end-stop detection.
3. **Semiconductor Equipment:** Where high repeatability is required in a small form factor.
---
### 4. Precautions for Use
* **Load Requirements:** Do not exceed the 100mA rating. Connecting this switch to a high-power motor or large relay without a buffer will weld the gold contacts shut.
* **Mechanical Over-travel:** Ensure the physical strike distance does not exceed the "Total Travel" limit specified in the datasheet to avoid damaging the internal spring mechanism.
- ⤷