154CV-300G-R
AI

The **154CV-300G-R** is a high-precision, media-isolated pressure sensor designed for applications requiring high reliability and compatibility with harsh environments. It is manufactured by TE Connectivity (formerly Measurement Specialties).
---
## 1. Core Specifications
The alphanumeric code "300G" indicates a 300 psi Gauge pressure range. Below are the primary technical parameters:
| Feature | Specification |
| :--- | :--- |
| **Pressure Range** | 0 to 300 psi |
| **Pressure Type** | Gauge (referenced to atmospheric pressure) |
| **Output Type** | Constant Voltage (0-100mV typical span) |
| **Input Excitation** | 1.0mA or 10V (typical) |
| **Accuracy** | ±0.1% to ±0.25% Non-linearity |
| **Operating Temp** | -40°C to +125°C |
| **Material** | 316L Stainless Steel |
---
## 2. Structural Design
The "154CV" series is known for its **Media-Isolated** architecture.
### Internal Components:
* **Sensing Die:** A micromachined piezoresistive silicon chip.
* **Oil Fill:** The sensor die is submerged in silicone oil.
* **Isolation Diaphragm:** A thin 316L stainless steel diaphragm protects the sensitive silicon chip from the liquid or gas being measured.
* **Housing:** A cylindrical stainless steel body (19mm diameter) designed for O-ring mounting.
---
## 3. Working Principle
1. **Pressure Application:** External pressure presses against the stainless steel diaphragm.
2. **Transfer:** The pressure is transferred through the internal silicone oil to the silicon sensing chip.
3. **Bridge Response:** The piezoresistive Wheatstone bridge on the chip changes resistance in proportion to the pressure.
4. **Signal Output:** The sensor produces a millivolt (mV) output signal that requires external amplification or signal conditioning to be read by a microcontroller.
---
## 4. Common Applications
Due to its rugged construction and high accuracy, the 154CV-300G-R is used in:
* **Industrial Process Control:** Monitoring pipelines and hydraulic systems.
* **Medical Instruments:** Dialysis machines or pressure-sensitive surgical tools.
* **Fresh Water/Wastewater:** Measurement in tanks where fluids might corrode standard silicon sensors.
* **Air Compressors:** High-cycle monitoring of pneumatic lines.
---
## 5. Wiring and Connectivity
This model typically features **ribbon cable or solder pads**. Because it is an uncompensated or minimally compensated sensor (depending on the specific "C" variant sub-type), it usually follows a standard bridge configuration:
1. **Pin 1:** +Excitation
2. **Pin 2:** +Output
3. **Pin 3:** -Output
4. **Pin 4:** -Excitation
- ⤷
What is the difference between Gauge (G) and Absolute (A) versions of this sensor?
- ⤷ How does temperature compensation affect the output signal of the 154CV?
- ⤷ What type of external amplifier is recommended for a 100mV span sensor?