5VTP4-R
AI

The **5VTP4-R** is a specific type of electronic fuse, belonging to the subminiature, slow-blow (time-delay) category. It is commonly used in power supplies, consumer electronics, and industrial controllers to protect circuits from overcurrent conditions.
### Technical Specifications
Below are the primary technical characteristics of the 5VTP4-R:
| Feature | Specification |
| :--- | :--- |
| **Part Number** | 5VTP4-R |
| **Current Rating** | 4 Amperes (4A) |
| **Voltage Rating (AC)** | 250 Volts |
| **Fuse Type** | Time-Delay / Slow-Blow (T) |
| **Form Factor** | 5x20mm (Subminiature) |
| **Termination Style** | Radial Leaded (Through-hole) |
| **Body Material** | Glass or Ceramic (depending on series variation) |
| **RoHS Compliant** | Yes (indicated by the "-R" suffix) |
---
### Key Components and Features
#### 1. Time-Delay Mechanism (Slow-Blow)
Unlike "Fast-Acting" fuses, the 5VTP4-R is designed to withstand temporary surges in current, such as the initial "inrush current" when a motor starts or a power supply is plugged in. It will only blow if the overcurrent persists beyond a specific time threshold.
#### 2. Radial Leaded Design
The "V" in the part number often signifies a vertical/radial lead configuration. Instead of fitting into a fuse clip, this part is soldered directly onto a Printed Circuit Board (PCB). This saves space and reduces assembly costs in mass production.
#### 3. Safety Compliance
The 5VTP4-R is typically rated under international standards such as:
* **UL/CSA:** North American safety standards.
* **IEC 60127:** International standard for miniature fuses.
* **RoHS:** Lead-free and environmentally friendly construction.
### Common Applications
* **Power Adapters:** Protecting internal circuitry from AC line surges.
* **LED Drivers:** Managing high inrush currents during startup.
* **Industrial Equipment:** Protecting small motors or control boards.
* **Consumer Electronics:** Used in televisions, chargers, and home appliances.
---
### Replacement Considerations
When replacing a 5VTP4-R, ensure the following parameters match exactly:
1. **Amperage:** Do not exceed 4A.
2. **Voltage:** Ensure the replacement is rated for at least 250V.
3. **Speed:** You must use a **Slow-Blow (T)** fuse. Using a Fast-Acting (F) fuse will cause it to blow immediately upon startup.