A-MCSSP60300-R-R
AI

The **A-MCSSP60300-R-R** is a specific technical component, typically identified as a **High-Performance Shielded Modular Patch Cord** (specifically a Cat6 or Cat6a SSTP/SFTP Ethernet cable). These cables are engineered for high-speed data environments where electromagnetic interference (EMI) is a concern.
---
### 1. Key Technical Specifications
The part number follows a modular naming convention used by manufacturers like **Assmann WSW Components**.
| Feature | Specification |
| :--- | :--- |
| **Category** | Cat6 (Gigabit Ethernet) |
| **Shielding Type** | S/FTP (Shielded Foiled Twisted Pair) |
| **Connector A** | RJ45 Male (with 50µ gold plating) |
| **Connector B** | RJ45 Male (with 50µ gold plating) |
| **Length** | 3.0 Meters (approx. 10 feet) |
| **Color** | Red |
| **Jacket Material** | LSZH (Low Smoke Zero Halogen) or PVC |
---
### 2. Electronic Component Breakdown
#### A. Internal Wiring (Conductors)
* **Gauge:** Typically 26 AWG or 27 AWG stranded copper.
* **Twisted Pairs:** The cable contains four pairs of wires. The "twisting" is a crucial electronic design choice to cancel out electromagnetic interference from external sources and crosstalk between neighboring pairs.
#### B. Shielding System (S/FTP)
This part features a dual-layer shielding architecture:
1. **Individual Foil Shield:** Each of the four pairs is wrapped in aluminum foil. This prevents "Internal Crosstalk" between the pairs.
2. **Outer Braid Shield:** An overall tinned copper braid surrounds all four pairs. This acts as a Faraday cage, protecting the signal from external High-Frequency Interference (RFI).
#### C. The RJ45 Connectors
* **Gold Plating:** The pins are usually plated with 50 micro-inches of gold. Gold is used because it provides excellent conductivity and is highly resistant to oxidation/corrosion over time.
* **Strain Relief Boot:** The "R-R" in the suffix often refers to the "Snagless" boot design, which protects the plastic locking tab of the electronic connector.
---
### 3. Application Use Cases
Due to its shielded nature, this part is used in environments where electronic "noise" is prevalent:
* **Data Centers:** High-density racks where many cables are bundled together.
* **Industrial Floors:** Near heavy machinery or power cables that generate EMI.
* **Medical Equipment:** Where signal integrity is critical for diagnostic data.
---
- ⤷
What is the difference between S/FTP and UTP shielding in electronic cables?
- ⤷ How does the 50u gold plating affect signal longevity?
- ⤷ Can this specific cable support 10-Gigabit Ethernet speeds?