BA2-B0-46-610-11D-C3
AI

The part number **BA2-B0-46-610-11D-C3** refers to a high-performance **Magnetic Hydraulic Circuit Breaker** manufactured by **Carling Technologies** (now part of Littelfuse). It belongs to the **B-Series**, which is highly versatile and used worldwide in telecommunications, marine, and industrial automation.
---
### 1. Specification Breakdown
Each segment of the part number defines a specific physical or electrical characteristic of the device:
| Segment | Code | Description |
| :--- | :--- | :--- |
| **Series** | **BA** | B-Series Circuit Breaker (Compact, 1-6 poles) |
| **Actuator** | **2** | Handle style (standard toggle) |
| **Poles** | **B0** | Two-pole configuration |
| **Circuit** | **46** | Series Trip (Current Trip) with auxiliary switch |
| **Rating** | **610** | 10.0 Amperes (Full load rating) |
| **Frequency** | **11** | DC Medium delay (for standard electronic loads) |
| **Terminals** | **D** | Screw Terminals (10-32 with washers) |
| **Actuator Color** | **C3** | White toggle with "ON/OFF" vertical markings |
---
### 2. Key Technical Features
* **Magnetic-Hydraulic Design:** Unlike thermal breakers, these are not affected by ambient temperature. They maintain their precise trip point regardless of whether the environment is freezing or hot.
* **Two-Pole Protection:** The "B0" designation indicates it can break two separate lines simultaneously, providing complete circuit isolation.
* **Delay Curve (11):** This is a "Medium Delay" specifically calibrated for DC circuits. It allows for short-duration inrush currents (like starting a small motor) but trips quickly on sustained overloads.
* **Interrupting Capacity:** Typically rated for 5,000 Amps (AIC), making it robust against high-fault current scenarios.
---
### 3. Common Applications
Due to its precision and reliability, this specific configuration is commonly found in:
1. **Marine Panels:** Protecting sensitive navigation electronics.
2. **Telecommunications:** Used in power distribution units (PDUs).
3. **Industrial Controls:** Protecting PLCs and 24V DC power supplies.
4. **Solar Systems:** Acting as a disconnect/protector for DC battery strings.
---
### 4. Comparison Table: Thermal vs. Magnetic (BA-Series)
| Feature | Thermal Breaker | BA2-B0-46-610... (Magnetic) |
| :--- | :--- | :--- |
| **Temperature Sensitivity** | High (trips early in heat) | None (stable trip point) |
| **Reset Time** | Must cool down first | Immediate reset possible |
| **Service Life** | Shorter | Very long (designed for precision) |
- ⤷
What is the difference between AC and DC delay curves for this model?
- ⤷ Can this circuit breaker be DIN-rail mounted?
- ⤷ What are the specific torque requirements for the 'D' type screw terminals?