The part number **CA2-B0-14-440-121-D** refers to a high-quality **Hydraulic-Magnetic Circuit Breaker** manufactured by **Carling Technologies** (specifically from their C-Series line).
Below is a detailed breakdown of its specifications and electrical characteristics.
---
### 1. Part Number Breakdown
The alphanumeric code follows Carling's specific nomenclature to define the mechanical and electrical properties:
| Segment | Code | Description |
| :--- | :--- | :--- |
| **Series** | `CA` | C-Series Circuit Breaker (Compact, high amperage) |
| **Actuator** | `2` | Two-pole configuration (Handles two lines) |
| **Polls/Mounting**| `B0` | Series Trip (Current sensing) with screw terminals |
| **Delay** | `14` | Medium Delay (Time delay for inductive loads) |
| **Rating** | `440` | **4.0 Amperes** current rating |
| **Voltage** | `121` | 277VAC (Max) or 80VDC (Max) |
| **Terminals** | `D` | 10-32 Screw Terminals with bus connectors |
---
### 2. Key Electrical Specifications
The CA-Series is designed for precision and reliability in harsh environments.
* **Current Rating:** 4.0 Amps.
* **Voltage Rating:** Supports up to 277V AC or 80V DC.
* **Interrupting Capacity:** Typically up to 5,000 Amps (AIC).
* **Trip Mechanism:** **Hydraulic-Magnetic.** Unlike thermal breakers, these are not affected by ambient temperature. They trip based purely on the magnetic field generated by the current.
* **Delay Curve 14:** This provides a "Medium Delay," which allows for brief nuisance surges (like a motor starting up) without tripping immediately, but provides fast protection against short circuits.
---
### 3. Physical & Mechanical Features
* **Form Factor:** Compact design suitable for panel mounting.
* **Number of Poles:** 2 (The unit will disconnect two separate lines simultaneously if a fault is detected on either).
* **Actuator Type:** Handle/Toggle switch (White with "On/Off" markings).
* **Terminal Type:** Standard 10-32 screw terminals, ensuring a secure vibration-resistant connection.
---
### 4. Typical Applications
Because of the Hydraulic-Magnetic technology and the medium time delay, this specific breaker is commonly used in:
* **Telecommunications:** Power distribution units (PDUs).
* **Marine Electronics:** Main panels and motor circuits.
* **Industrial Automation:** Protection for sensitive control circuits.
* **Renewable Energy:** Inverters and battery management systems.
---
- ⤷
What is the difference between a thermal breaker and a hydraulic-magnetic breaker?