CBS502424-R
AI

The **CBS502424-R** is a high-reliability, isolated DC-DC converter manufactured by **Cosel**. It is part of the CBS series, which is designed for industrial and telecommunications applications where high power density and a compact footprint (Half-Brick size) are required.
---
### 1. Key Technical Specifications
The model number "CBS502424" encodes its primary ratings:
| Feature | Specification |
| :--- | :--- |
| **Series Name** | CBS Series (Half-Brick) |
| **Output Power** | 50 Watts |
| **Input Voltage (Nominal)** | 24V DC |
| **Input Voltage Range** | 18V to 36V DC |
| **Output Voltage** | 24V DC |
| **Output Current** | 2.1 Amperes |
| **Suffix "-R"** | Remote ON/OFF (Negative Logic) |
---
### 2. Major Electronic Components & Design Features
The internal architecture of the CBS502424-R focuses on efficiency and thermal management:
* **Isolation Barrier:** Provides high-grade electrical isolation (typically 1,500V AC or 2,000V DC) between the input and output stages to protect sensitive downstream components.
* **Synchronous Rectification:** Uses high-efficiency MOSFETs instead of traditional diodes in the secondary stage to minimize power loss and heat generation.
* **Built-in Protection Circuits:**
* **Overcurrent Protection (OCP):** Automatically recovers when the fault is removed.
* **Overvoltage Protection (OVP):** Shuts down the unit if output voltage exceeds safety limits.
* **Thermal Protection:** Integrated sensors shut the unit down if the baseplate temperature exceeds $100^{\circ}C$.
* **Remote Sensing:** Allows the converter to compensate for voltage drops across the wiring between the power supply and the load.
---
### 3. Physical & Mechanical Attributes
| Attribute | Detail |
| :--- | :--- |
| **Package Size** | Half-Brick ($57.9 \times 12.7 \times 61$ mm) |
| **Cooling Method** | Conduction cooling via a baseplate (Requires external heatsink or cold plate) |
| **Mounting Type** | Through-hole (PCB Mount) |
---
### 4. Meaning of the "-R" Suffix
In Cosel's nomenclature, the **-R** suffix signifies **Negative Logic Remote Control**.
* **Standard (No Suffix):** The unit is ON when the RC pin is open/High.
* **-R Suffix:** The unit is ON when the RC pin is pulled Low (connected to -Vin). This is often preferred for safety in industrial systems where a disconnected wire should result in the power supply being OFF.
---
- ⤷
What are the specific thermal requirements for the CBS502424-R baseplate?
- ⤷ How do I implement the Remote Sensing pins to compensate for voltage drops?
- ⤷ What is the difference between the CBS series and the DHS series from Cosel?