FAS-35-R
AI

The **FAS-35-R** is a specialized high-performance fire alarm strobe (typically manufactured by brands like **Mircom** or **Secutron**). It is designed for visual signaling in life safety systems.
Below is a breakdown of its electronic components and technical specifications.
---
### 1. Core Electronic Components
The FAS-35-R operates using a combination of high-voltage discharge circuitry and synchronization logic.
| Component | Function |
| :--- | :--- |
| **Xenon Flash Tube** | The primary light source that produces a high-intensity white flash. |
| **Trigger Transformer** | Steps up the voltage to ionize the gas inside the xenon tube, initiating the flash. |
| **Energy Storage Capacitor** | Stores electrical energy from the input line and releases it rapidly to power the strobe. |
| **Inverter Circuit** | Converts the low-voltage DC input (typically 24V) into the high voltage required by the capacitor. |
| **Synchronization Module** | Ensures multiple strobes in a single area flash at the exact same moment to prevent photosensitive epilepsy triggers. |
---
### 2. Technical Specifications
The electronic performance of the FAS-35-R is governed by its power draw and light output.
* **Operating Voltage:** Typically 24VDC (Filtered) or FWR (Full Wave Rectified).
* **Candela Rating:** This model is usually rated at **35 Candela**, which determines the intensity of the light.
* **Mounting:** Designed for wall-mount applications (indicated by the "R" often referring to Red housing).
* **Polarization:** The unit is electronically polarized for use with supervised fire alarm circuits.
---
### 3. Wiring and Integration
The FAS-35-R uses a standard 2-wire terminal block system for integration into a Fire Alarm Control Panel (FACP).
```mermaid
graph LR
A[FACP 24VDC Output] --> B[FAS-35-R Positive Input]
A[FACP Ground] --> C[FAS-35-R Negative Input]
C --> D[Next Device/End of Line Resistor]
```
### 4. Key Features
1. **Low Current Draw:** Optimized electronic design to allow more devices on a single Notification Appliance Circuit (NAC).
2. **Stable Flash Rate:** Maintains a consistent 1Hz (60 flashes per minute) as required by NFPA 72.
3. **Supervised Circuitry:** Includes a bypass diode to allow the fire panel to check for "open circuit" faults when the system is in standby.
---
- ⤷
What is the maximum current draw for the FAS-35-R at 24VDC?
- ⤷ Does the FAS-35-R require a specific synchronization protocol module?
- ⤷ Can the FAS-35-R be used for ceiling mount applications?