The **FAS-D1-R** is an addressable remote indicator module, typically used in fire alarm systems to provide a visual signal when a hidden detector (such as one located in a ceiling void or a locked room) is activated.
Below is an explanation of its electronic components, technical specifications, and wiring structure.
---
### 1. Key Electronic Components
The device is a combination of optical signaling and digital communication electronics.
| Component | Function |
| :--- | :--- |
| **High-Intensity LEDs** | Provides a bright red visual alarm signal, visible from a wide angle. |
| **Addressable IC** | A microprocessor or logic chip that allows the fire alarm control panel (FACP) to identify and trigger this specific unit. |
| **DIP Switches / Programmer Port** | Used to set the unique digital address of the module on the SLC loop. |
| **Current Limiting Resistors** | Protects the LEDs from overcurrent when the alarm circuit is active. |
| **Blocking Diode** | Ensures polarity protection and prevents reverse current flow. |
---
### 2. Technical Specifications
The FAS-D1-R operates on the signaling line circuit (SLC) and draws minimal power during standby.
| Feature | Specification (Typical) |
| :--- | :--- |
| **Operating Voltage** | 15V - 32V DC (Loop Powered) |
| **Standby Current** | < 200 µA |
| **Alarm Current** | ~2mA - 5mA (LED active) |
| **Communication Protocol** | Digital / Addressable |
| **Operating Temperature** | -10°C to 50°C |
| **Relative Humidity** | 10% to 95% (Non-condensing) |
---
### 3. Wiring and Connection Logic
The FAS-D1-R is connected to the fire alarm system via a two-wire loop. Unlike conventional remote lamps that connect directly to a detector's base, addressable units like the FAS-D1-R are mapped through software.
#### Standard Wiring Diagram Block:
```text
[FACP Loop Output] (+) ----+---- [FAS-D1-R Terminal L+]
|
[FACP Loop Output] (-) ----+---- [FAS-D1-R Terminal L-]
```
* **Polarity Sensitivity:** The device is polarity sensitive; swapping the positive and negative leads will prevent the device from communicating with the panel.
* **Addressing:** The module must be assigned a unique address (e.g., Address 052) so the control panel knows which specific room or area is in alarm.
---
### 4. Functional Operation
1. **Polling:** The fire panel constantly sends a digital "heartbeat" to the FAS-D1-R.
2. **Triggering:** When a linked smoke detector senses fire, the panel sends a command specifically to the FAS-D1-R's address.
3. **Indication:** The onboard transistors switch the circuit, lighting the Red LEDs to alert personnel to the fire's location.
- ⤷How do you set the digital address on a FAS-D1-R module?
- ⤷ Can the FAS-D1-R be used with conventional (non-addressable) fire systems?
- ⤷ What is the maximum number of FAS-D1-R units allowed on a single SLC loop?