M2AC-AC5-R/Q
AI

The **M2AC-AC5-R/Q** is a specific model within the **M2 Series** of signal conditioners manufactured by **M-System**. This device is a high-performance AC current transducer designed to convert an alternating current (AC) input into a standard DC output signal.
---
### 1. Model Breakdown (Part Number Analysis)
Understanding the suffix codes helps identify the specific electronic characteristics of this unit:
| Code | Component Segment | Specification |
| :--- | :--- | :--- |
| **M2AC** | Base Model | AC Current Transducer (Average sensing) |
| **AC5** | Input Range | 0 – 5A AC |
| **R** | Output Signal | 4 – 20mA DC (Current Output) |
| **Q** | Power Input | 100 – 240V AC |
---
### 2. Key Electronic Specifications
The internal circuitry is designed for industrial-grade isolation and signal processing:
* **Sensing Method:** Average sensing, RMS calibrated. This means it calculates the average value of the AC wave and scales it to represent the RMS value (ideal for pure sine waves).
* **Isolation Structure:** 3-way isolation. The **Input**, **Output**, and **Power** terminals are electrically isolated from each other.
* **Isolation Resistance:** $\ge$ 100 M$\Omega$ with 500V DC.
* **Dielectric Strength:** 2000V AC @ 1 minute (Input to output to power to ground).
* **Response Time:** $\le$ 0.5 seconds (0 – 90%).
* **Overload Capacity:** 10 times the rated current for 3 seconds; 2 times continuously.
---
### 3. Wiring and Terminals
The unit typically uses a M3.5 screw terminal base. Below is a general representation of the electronic connections:
| Terminal No. | Function | Description |
| :--- | :--- | :--- |
| **1** | Input (U) | AC Current Input (0-5A) |
| **2** | Input (V) | AC Current Input (0-5A) |
| **4** | Output (+) | 4-20mA DC Positive |
| **5** | Output (-) | 4-20mA DC Negative |
| **7** | Power (L) | 100-240V AC Line |
| **8** | Power (N) | 100-240V AC Neutral |
---
### 4. Application Logic
The electronic internal logic follows this signal flow:
1. **Input Stage:** A small internal current transformer (CT) steps down the 0-5A AC signal.
2. **Rectification/Filtering:** The signal is rectified and smoothed to determine the average AC amplitude.
3. **Amplification:** An operational amplifier scales the signal to the calibrated range.
4. **Output Stage:** A voltage-to-current converter drives the 4-20mA loop, ensuring the signal remains constant despite fluctuations in load resistance (up to 750 $\Omega$).
---
- ⤷