数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

  • M2AC-AD3-R2/CE

  • AI
    The **M2AC-AD3-R2/CE** is a high-performance, signal-conditioning transducer manufactured by **M-System** (now part of MG CO., LTD.). It is primarily used in industrial automation to convert an AC current input into a standard DC output signal. --- ## 1. Core Technical Specifications The model number breakdown reveals its primary electronic characteristics: | Feature | Specification | | :--- | :--- | | **Input Signal** | 0 – 5A AC (Standard CT output) | | **Output Signal** | 4 – 20mA DC | | **Power Supply** | 100 – 240V AC (Standard) | | **Isolation** | 3-Way Isolation (Input, Output, Power) | | **Accuracy** | ±0.3% | | **Response Time** | ≤ 0.5 seconds (0 to 90%) | | **Mounting** | DIN Rail | --- ## 2. Key Electronic Components & Design ### A. Input Stage (Current Transformer) The device contains an internal sensing transformer that steps down the high AC current (0-5A) to a low-voltage level suitable for internal electronic processing. This provides the first layer of galvanic isolation. ### B. Signal Conversion (True RMS vs. Mean Value) Depending on the specific configuration of the AD3 series: * **Rectification:** It typically uses a precision rectifier circuit to convert the AC waveform into a proportional DC voltage. * **Filtering:** Low-pass filters are used to smooth the ripple from the AC-to-DC conversion to ensure a steady 4-20mA output. ### C. 3-Way Isolation Circuitry This is a critical safety and signal integrity feature. The electronics are divided into three isolated sections: 1. **Input Circuit:** Protected against high-voltage surges from the current transformer. 2. **Output Circuit:** Isolated to prevent ground loops from affecting the PLC or controller. 3. **Power Circuit:** Uses a switching regulator to isolate the mains power supply from the sensitive measurement signals. ### D. Calibration Potentiometers On the front panel, there are typically two multi-turn trimmers: * **Zero Adjustment:** Used to calibrate the 4mA floor. * **Span Adjustment:** Used to calibrate the 20mA ceiling. --- ## 3. CE Marking & Protection The **/CE** suffix indicates that the electronic components comply with European Directives regarding: * **EMC (Electromagnetic Compatibility):** The device is shielded against radio frequency interference (RFI) and does not emit excessive electronic noise. * **LVD (Low Voltage Directive):** Ensures the internal insulation and spacing between components can withstand high voltage without breakdown. --- ## 4. Typical Connection Diagram ```text [ SOURCE AC LINE ] | (CT) 0-5A | +-----|-----+ | (1) (2) | <-- Input Terminals | | | [M2AC] | | | | (4) (5) | <-- Output (4-20mA DC) to PLC | (7) (8) | <-- Power Supply (100-240V AC) +-----------+ ``` ---
    ✨ Follow-up Questions
    • ⤷ What is the maximum allowable load resistance for the 4-20mA output on this model?
    • ⤷ Can the M2AC-AD3 handle non-sinusoidal (distorted) waveforms?
    • ⤷ How do I perform a field calibration using the Zero and Span trimmers?