M2AC-AD3-R2/Q
AI

The **M2AC-AD3-R2/Q** is a high-performance, plug-in type signal conditioner (transducer) manufactured by **M-System**. It is specifically designed to convert an AC current input into a standard instrumentation DC signal.
---
### 1. Technical Specifications
The "R2/Q" suffix indicates specific power and configuration options. Below are the core technical specifications:
| Feature | Specification |
| :--- | :--- |
| **Input Type** | AC Current (e.g., 0–1A, 0–5A AC) |
| **Output Type** | DC Voltage or Current (e.g., 4–20mA, 0–10V) |
| **Power Input** | 110V AC (Standard for R2 designation) |
| **Accuracy** | ±0.3% to ±0.5% (depending on specific range) |
| **Response Time** | ≤ 0.5 seconds (0 to 90%) |
| **Isolation** | 3-way isolation (Input to Output to Power) |
| **Mounting** | Plug-in socket (surface or DIN rail) |
---
### 2. Core Electronic Components
The device utilizes several internal stages to process the signal:
1. **Input Transformer:** Provides primary isolation and steps down the AC current to a level manageable by the internal circuitry.
2. **Rectifier & Filter Circuit:** Converts the AC waveform into a pulsating DC signal and smooths it to determine the RMS or average value.
3. **Isolation Amplifier:** Uses optical or magnetic coupling to ensure the input, output, and power supply are electrically isolated (typically up to 2000V AC).
4. **Output Driver:** A precision operational amplifier stage that scales the signal to the desired DC range (e.g., 4–20mA).
5. **Power Module:** An internal AC/DC converter that regulates the 110V AC input to power the internal active components.
---
### 3. Part Number Breakdown (M2AC-AD3-R2/Q)
* **M2AC:** Series identification (AC Input Signal Conditioner).
* **AD3:** Specific input/output configuration (Standard AC Current to DC).
* **R2:** Power Supply code (typically 100–120V AC).
* **Q:** Indicates "Special Order" or "Option Specified." This usually means the device has custom calibration, specific coating (like tropicalization), or a non-standard frequency response.
---
### 4. Application Usage
This part is commonly used in industrial automation for:
* **Motor Load Monitoring:** Converting high AC motor currents into 4-20mA signals for a PLC.
* **Power Management:** Feeding current data into SCADA systems.
* **Safety Isolation:** Protecting sensitive control electronics from high-voltage AC power lines.
- ⤷
What are the specific input and output ranges for the AD3 configuration?
- ⤷ What does the /Q option specifically modify in this model?
- ⤷ How do I wire the M2AC-AD3-R2/Q to a PLC?