M2AC-AZ1-R2
AI

The **M2AC-AZ1-R2** is a high-performance, plug-in type signal conditioner (isolator) manufactured by **M-System**. It is designed to convert an AC current input into a standard DC output signal, providing electrical isolation between the input, output, and power source.
---
### 1. Technical Specifications
Below are the primary electronic characteristics of the M2AC-AZ1-R2:
| Feature | Specification |
|:---|:---|
| **Input Signal** | 0 – 1 A AC |
| **Output Signal** | 4 – 20 mA DC |
| **Power Input** | 100 – 240V AC (50/60 Hz) |
| **Accuracy** | ±0.3% |
| **Response Time** | ≤ 0.5 seconds (0 – 90%) |
| **Isolation** | Input to Output to Power (2000V AC) |
| **Mounting** | Surface or DIN rail (Plug-in socket) |
---
### 2. Core Electronic Components & Architecture
The device functions through several internal stages to ensure signal integrity and safety:
#### A. Input Stage (Current Transformer)
The "AZ1" designation indicates a 0-1A AC input range. Internally, the device uses a miniature precision current transformer to step down the input current while providing the first layer of galvanic isolation.
#### B. Rectification & Filtering
Since the input is AC and the output must be DC, the internal circuitry employs a bridge rectifier and a smoothing filter. This converts the sinusoidal AC wave into a proportional DC voltage level.
#### C. Isolation Barrier (Optical/Magnetic)
The M2 series utilizes a 3-way isolation scheme. This prevents "ground loops" and protects sensitive control equipment (like PLCs) from high-voltage surges on the input line.
* **Input-to-Output:** Protects the controller.
* **Input-to-Power:** Protects the local power grid.
#### D. Output Driver (4-20mA Loop)
The final stage is a constant-current generator. It translates the processed internal signal into a standard 4-20mA current loop. The "R2" in the part number specifies the power supply requirement (standard AC power).
---
### 3. Wiring Configuration
The unit typically uses an 8-pin or 11-pin base (depending on the specific socket).
```text
Pin Connections (General Layout):
1. Output (+)
2. Output (-)
3. AC Power (L)
4. AC Power (N)
5. Input (U)
6. Input (V)
```
---
### 4. Key Applications
* **Motor Load Monitoring:** Converting high AC currents from motors into signals a PLC can read.
* **Signal Normalization:** Standardizing different AC current levels for a unified control system.
* **Safety:** Isolating high-voltage AC field equipment from low-voltage DC control rooms.
- ⤷How do I calibrate the Zero and Span on this unit?
- ⤷ What is the difference between the R2 and M2 power suffix?
- ⤷ Can this unit handle distorted AC waveforms or harmonics?