M2PHS2H-151-R/Q
AI

The **M2PHS2H-151-R/Q** is a high-precision, industrial-grade **Current Transducer** (specifically a Hall Effect current sensor) manufactured by **M-System** (now part of MG CO., LTD). It is designed to measure AC current and convert it into a proportional standard DC signal (such as 4-20mA or 0-10V).
### 1. Key Technical Specifications
| Parameter | Specification Details |
| :--- | :--- |
| **Model Series** | M2PHS (Plug-in Current Transducer) |
| **Input Signal** | 0 – 1 A AC or 0 – 5 A AC (Standard range) |
| **Output Signal** | Configurable (e.g., 4-20mA DC, 1-5V DC, etc.) |
| **Accuracy** | ±0.3% of span |
| **Response Time** | ≤ 0.5 seconds (0 to 90%) |
| **Isolation** | 2000V AC @ 1 minute (Input to output to power to ground) |
| **Mounting** | Surface or DIN rail mounting (Plug-in base) |
---
### 2. Breakdown of the Model Suffix (151-R/Q)
Based on M-System's nomenclature, here is the breakdown of the electronic configuration:
* **M2PHS**: The base model for an AC Current Transducer (Average sensing).
* **2H**: Represents the physical housing/connection type (usually a 2-wire or specific plug-in base configuration).
* **1**: Specifies the Input (typically 0–1A AC).
* **5**: Specifies the Output (typically 4–20mA DC).
* **1**: Specifies the Power Input (typically 100V AC).
* **-R**: Indicates the Power Supply voltage (R usually denotes **24V DC**).
* **/Q**: Indicates a **Special Option** code. This usually means the unit has specific custom calibrations or conformal coating for harsh environments.
---
### 3. Electronic Components and Working Principle
The internal circuitry of this part consists of four main stages:
1. **Input Transformer/Shunt:** The AC input is isolated via an internal transformer to step down the current to a level safe for the internal electronics.
2. **Rectifier & Filter Circuit:** Since the "PHS" series uses **Average Sensing**, the AC waveform is rectified into DC and filtered. It is calibrated to represent the RMS value of a pure sine wave.
3. **Isolation Barrier:** Uses an opto-isolator or transformer-based isolation to ensure that high voltage on the input side does not damage the PLC or controller on the output side.
4. **Signal Conditioner/Amplifier:** An operational amplifier (Op-Amp) circuit scales the signal to the desired output range (e.g., 4-20mA).
---
### 4. Application Usage
* **Power Monitoring:** Measuring the current draw of electric motors to detect overloads.
* **PLC Interfacing:** Converting high-voltage AC lines into low-voltage DC signals for data acquisition.
* **Energy Management:** Monitoring building or factory power consumption.
- ⤷
What is the difference between average sensing and true RMS sensing in these transducers?
- ⤷ How do I wire the 24V DC power supply to the -R version?
- ⤷ What specific custom options does the /Q suffix usually refer to?