M2RTS-R-34-R2/CE
AI

The **M2RTS-R-34-R2/CE** is a high-precision, industrial-grade RTD (Resistance Temperature Detector) transmitter from the M2 Series by **M-System**. It is designed to convert signals from a temperature sensor into a standard industrial DC output.
---
## 1. Core Technical Specifications
The following table breaks down the electronic characteristics of this specific model:
| Component / Feature | Specification Details |
| :--- | :--- |
| **Model Series** | M2RTS (RTD Transmitter) |
| **Input Type** | Pt 100 (ITS-90) RTD sensor |
| **Power Input (R)** | 24V DC |
| **Output Type (34)** | 0 – 10V DC (Current drive ≥ 1mA) |
| **Mounting (R2)** | Plug-in base (Standard M-System 11-pin) |
| **Certification (CE)** | European Conformity (EMC & Low Voltage Directive) |
| **Accuracy** | ±0.1% of span |
| **Response Time** | ≤ 0.5 seconds (0 – 90%) |
---
## 2. Detailed Electronic Architecture
### A. Input Section (RTD Interface)
The device is designed for **3-wire Pt 100** sensors.
- **Lead Wire Resistance Compensation:** The electronic circuit compensates for the resistance of the lead wires (up to 20 $\Omega$ per wire) to ensure the temperature reading is not skewed by the distance between the sensor and the transmitter.
- **Excitation Current:** It applies a very small, stable current to the RTD to prevent "self-heating," which would otherwise cause measurement errors.
### B. Signal Conditioning & Isolation
- **Galvanic Isolation:** This model features **Three-way Isolation** (Input to Output to Power). This prevents ground loops and protects sensitive PLC/DCS equipment from high-voltage surges on the field side.
- **Linearization:** RTD signals are inherently non-linear. The internal circuitry provides linear output proportional to the temperature, not just the resistance.
### C. Output Section
The "34" designation indicates a **0 – 10V DC** voltage output.
- **Short-circuit Protection:** The output electronics are designed to withstand brief short circuits without permanent damage.
- **Zero/Span Adjustments:** Accessible from the front panel, these allow for electronic calibration fine-tuning (usually ±5%).
---
## 3. Wiring Configuration
To ensure proper electronic operation, the pins on the 11-pin base are typically assigned as follows:
```text
PIN | FUNCTION
-----|------------------
1 | Output (+)
2 | Output (-)
3 | Input (RTD A)
4 | Input (RTD B)
5 | Input (RTD B')
7 | Power (L+) 24V DC
8 | Power (N-) 0V
```
---
## 4. Operational Indicators
The unit typically features a **Front LED** that indicates the status of the internal power supply. If the electronics are functioning and the 24V DC input is stable, the LED remains illuminated.
---
- ⤷