M2RTS-R-3G-R/UL
AI

The **M2RTS-R-3G-R/UL** is a high-performance electronic signal transducer/transmitter manufactured by **M-System**. It is primarily used in industrial automation to convert a temperature input (from a Resistance Temperature Detector - RTD) into a standard DC output signal.
The suffix `/UL` indicates that the unit is UL-listed for safety standards.
---
### 1. Key Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Model Series** | M2-Series (Mini-M) |
| **Input Type** | RTD (Resistance Temperature Detector) |
| **Output Type** | DC Current or Voltage (Standard 4–20 mA or 0–10V) |
| **Power Input** | 100 – 240V AC (indicated by "3G" code) |
| **Accuracy** | ±0.1% of span |
| **Response Time** | ≤ 0.5 seconds (0 to 90%) |
| **Isolation** | 3-way isolation (Input to Output to Power) |
| **Mounting** | Plug-in socket (DIN Rail or Surface) |
---
### 2. Breakdown of the Part Number
The alphanumeric code describes the specific hardware configuration:
* **M2**: The "Mini-M" family, known for a compact, plug-in design that reduces wiring time.
* **RTS**: Function identifier for an **RTD Transmitter**.
* **R**: Specific input range/type configuration (often indicates standard RTD like Pt 100).
* **3G**: Power supply code. In M-System nomenclature, this typically refers to **100 – 240V AC**.
* **R**: Output code. Usually represents a specific DC output (like 4–20mA DC).
* **UL**: Certified by Underwriters Laboratories for use in North American markets.
---
### 3. Electronic Functional Components
The internal circuitry is divided into three primary isolated sections to prevent ground loops and protect sensitive equipment:
#### A. Input Section (Signal Conditioning)
* **Leadwire Compensation:** Uses a 3-wire bridge circuit to cancel out the resistance of the wires leading to the RTD sensor.
* **Linearization:** Since RTDs are not perfectly linear, the electronics apply a linearization curve to ensure the output is proportional to the actual temperature.
#### B. Isolation & Processing
* **Galvanic Isolation:** Uses optical or magnetic couplers to ensure there is no electrical path between the high-voltage power source, the field sensor, and the PLC/Controller.
* **A/D and D/A Conversion:** Converts the analog resistance into a digital signal for precise processing, then back to a stable analog output.
#### C. Output Section
* **Current/Voltage Driver:** A high-precision amplifier that maintains the 4–20mA loop (or voltage) regardless of the load resistance (up to a certain limit).
---
### 4. Application Use Case
This part is typically used in chemical plants, power generation, or HVAC systems where a temperature sensor (RTD) is located far from the control room. The **M2RTS** converts the weak resistance signal into a robust 4–20mA signal that can travel long distances without interference.
---
- ⤷What are the specific wiring diagrams for the 3-wire RTD input on this model?
- ⤷ What is the maximum load resistance for the 4-20mA output version?
- ⤷ How do I perform a field calibration using the Zero and Span adjustments?