M2RTS-R-C3-R2/CE
AI

The **M2RTS-R-C3-R2/CE** is a high-precision, industrial-grade RTD (Resistance Temperature Detector) transmitter. It is part of the M2 series manufactured by **M-System**. This device is designed to convert temperature signals from an RTD sensor into a linearized standard DC output.
---
## 1. Technical Specifications Table
| Feature | Description |
| :--- | :--- |
| **Model Series** | M2RTS (Mini-M Series) |
| **Input Type** | RTD (Pt 100, JPt 100, etc.) |
| **Output Type** | DC Voltage or Current (Configurable) |
| **Power Input** | 24V DC |
| **Configuration** | Plug-in structure |
| **Precision** | ±0.1% of span |
| **Isolation** | 3-way (Input to Output to Power) |
| **Certification** | CE Marking |
---
## 2. Break-down of the Part Number
The alphanumeric suffix indicates the specific electronic hardware configuration:
* **M2RTS**: Base model for an RTD Transmitter (Mini-M Series).
* **-R**: Power Input code. Typically indicates **24V DC**.
* **-C3**: Output Signal code. Represents a specific DC range (often **1 – 5V DC** or **4 – 20mA** depending on factory settings).
* **-R2**: Options/Revision code. Often refers to specific terminal types or high-density mounting features.
* **CE**: Confirms compliance with European safety, health, and environmental protection standards.
---
## 3. Electronic Architecture & Components
The internal electronics are divided into three primary functional blocks:
### A. Input Stage (Signal Conditioning)
* **Burnout Protection:** Includes circuits to detect if the RTD wire is broken. It can be set to "Upscale" (max output) or "Downscale" (min output) upon failure.
* **Linearization:** Since RTDs are not perfectly linear, the internal microprocessor applies a linearization curve to ensure the output is proportional to the actual temperature.
### B. Isolation Barrier
* **Galvanic Isolation:** Uses optoisolators or transformers to separate the input, output, and power circuits. This prevents ground loops and protects sensitive PLC/DCS equipment from high-voltage surges on the sensor side.
### C. Output Stage
* **D/A Converter:** Converts the processed digital temperature data back into an analog voltage or current signal.
* **Zero/Span Adjustments:** Located on the front panel, these potentiometers allow for fine-tuning the electronic calibration without specialized software.
---
## 4. Key Advantages
1. **Compact Design:** The "Mini-M" footprint saves significant space on DIN rails.
2. **High Reliability:** Designed for 24/7 industrial operation with high MTBF (Mean Time Between Failures).
3. **Low Heat Dissipation:** Efficient electronic design prevents the unit from overheating in tightly packed enclosures.
- ⤷
How do you calibrate the Zero and Span on the M2RTS?
- ⤷ What are the specific wiring requirements for a 3-wire RTD input?
- ⤷ Can the output signal be changed from Voltage to Current in the field?