M2RTS-R-CC-R2/Q
AI

The **M2RTS-R-CC-R2/Q** is a high-precision, plug-in type RTD (Resistance Temperature Detector) transmitter manufactured by **M-System**. It is designed to convert temperature signals from an RTD into a standard process signal (like 4-20mA DC or 0-10V DC).
Below is the breakdown of its electronic components, specifications, and functions.
---
### 1. Model Code Breakdown
| Segment | Meaning | Specification |
| :--- | :--- | :--- |
| **M2RTS** | Series Name | Mini-M Series RTD Transmitter |
| **-R** | Input Type | RTD (Pt 100, JPt 100, etc.) |
| **-CC** | Output Code | Dual Output (Current/Current or as specified) |
| **-R2** | Power Input | 24V DC |
| **-Q** | Special Option | Often indicates "Quality" or "Custom Specification" (e.g., specific coating) |
---
### 2. Key Electronic Components & Internal Functions
The device operates using several critical stages to ensure signal integrity:
* **A/D Converter (Front End):** Converts the analog resistance value from the RTD into a digital signal. It includes **Burnout Protection circuitry**, which forces the output to a specific level (high or low) if the sensor wire breaks.
* **Linearization Circuitry:** RTD resistance change is not perfectly linear relative to temperature. This electronic stage applies a curve-correction algorithm to ensure the output is proportional to the actual temperature.
* **Galvanic Isolation:** The "R2" configuration typically features 3-way isolation:
* **Input to Output**
* **Input to Power**
* **Output to Power**
* *Benefit:* Prevents ground loops and protects sensitive PLC/DCS inputs from high-voltage surges.
* **Potentiometers (Zero/Span):** Located on the front panel, these allow for manual fine-tuning of the zero point (4mA) and the full-scale span (20mA).
---
### 3. Technical Specifications
| Feature | Description |
| :--- | :--- |
| **Input Signal** | 3-wire RTD (standard 100Ω Platinum) |
| **Input Resistance** | 1MΩ minimum |
| **Excitation Current** | Approx. 0.2mA (to prevent self-heating of the RTD) |
| **Output Signal** | 4 – 20 mA DC (for -CC configuration) |
| **Accuracy** | ±0.1% of span |
| **Response Time** | ≤ 0.5 seconds (0 – 90%) |
| **Housing Material** | Flame-resistant resin (Black) |
---
### 4. Wiring Diagram Overview
```text
Terminal | Function
-------------------
1 | Output 1 (+)
2 | Output 1 (-)
3 | Output 2 (+)
4 | Output 2 (-)
5 | RTD Input (A)
6 | RTD Input (B)
7 | RTD Input (B')
8 | Power (+) 24V DC
9 | Power (-) 0V
```
- ⤷