M2RTS-R-CZ-R2/CE
AI

The **M2RTS-R-CZ-R2/CE** is a high-precision, industrial-grade RTD (Resistance Temperature Detector) transmitter manufactured by **M-System**. It is designed to convert signals from a temperature sensor (typically Pt100) into a standard analog signal (like 4-20mA or 1-5V DC).
### 1. Key Technical Specifications
| Feature | Description |
| :--- | :--- |
| **Model Series** | M2RTS (Plug-in Temperature Transmitter) |
| **Input Type** | RTD (Resistance Temperature Detector) |
| **Output** | Field-configurable analog signal (Current or Voltage) |
| **Power Input** | Options typically include 100–240V AC or 24V DC |
| **Accuracy** | ±0.1% of span |
| **Response Time** | $\leq$ 0.5 seconds (0 to 90%) |
| **Isolation** | 3-way isolation (input to output to power) |
---
### 2. Breakdown of the Model Suffix (R-CZ-R2/CE)
Based on M-System's nomenclature, the code breaks down as follows:
* **R**: Specifies the Output type (often signifies a specific voltage/current range or a special characteristic).
* **CZ**: Often refers to the **Input Sensor Type**. In this series, 'Z' usually indicates a custom or specified range for a Pt100 or Pt1000 sensor.
* **R2**: Indicates the **Power Supply**. "R2" typically corresponds to **11V – 27V DC**.
* **CE**: This is the **Certification Mark**, indicating the unit complies with European Economic Area (EEA) health, safety, and environmental protection standards.
---
### 3. Internal Electronic Components & Functionality
The device operates using several critical electronic stages:
1. **Linearization Circuit**: RTDs are not perfectly linear. The internal electronics apply a linearization algorithm to ensure the output is proportional to the temperature, not the resistance.
2. **Burnout Protection**: A safety feature that drives the output to a specific limit (e.g., above 20mA or below 4mA) if the sensor wire breaks.
3. **Galvanic Isolation**: Uses optoisolators or transformers to prevent electrical noise and ground loops from traveling between the field sensor and the PLC/DCS.
4. **Zero/Span Adjustments**: Located on the front panel, these potentiometers allow for fine-tuning the electronic calibration in the field.
---
### 4. Wiring Pin-out (General Reference)
```text
Terminal | Function
---------|--------------------
1 | Output (+)
2 | Output (-)
3 | Power (L/+ for DC)
4 | Power (N/- for DC)
5 | RTD Input (A)
6 | RTD Input (B)
7 | RTD Input (B') - For 3-wire compensation
```
---
- ⤷
What is the specific temperature range configured for the 'CZ' input suffix?
- ⤷ How do I calibrate the Zero and Span on this transmitter?
- ⤷ Can this model be mounted on a standard DIN rail?