M2RTS-R-DG-R2/N
AI

The **M2RTS-R-DG-R2/N** is a specific model of a **Resistance Thermometer Transmitter** (RTD Transmitter) belonging to the M2 Series manufactured by **M-System (MG CO., LTD.)**.
This electronic component is designed to convert a signal from an RTD (Resistance Temperature Detector) sensor into a standard analog process signal (like 4–20mA or 1–5V DC).
---
## 1. Technical Specifications Breakdown
The alphanumeric code describes the specific configuration of the device:
| Code Segment | Description | Details |
| :--- | :--- | :--- |
| **M2RTS** | Model Series | RTD Transmitter (M2 Series) |
| **-R** | Input Signal | Pt 100 (JIS '97, IEC) |
| **-DG** | Output Signal | 0 – 10V DC / 4 – 20mA DC (Multi-output) |
| **-R2** | Power Input | 24V DC |
| **-N** | Options | No special options / Standard |
---
## 2. Key Electronic Components & Features
### A. Input Stage (RTD Interface)
* **Sensor Type:** Designed primarily for Pt100 platinum resistance thermometers.
* **Burnout Protection:** Includes an electronic circuit that detects a broken wire in the RTD. It can be configured to "Upscale" (max output) or "Downscale" (min output) upon failure.
* **Linearization:** The internal circuitry compensates for the non-linear relationship between temperature and resistance in platinum sensors.
### B. Signal Conditioning & Isolation
* **Isolation:** This unit features **three-way isolation** (Input to Output to Power). This prevents ground loops and protects sensitive PLC/DCS equipment from high-voltage surges on the field side.
* **Adjustment Potentiometers:** Located on the front panel for "Zero" and "Span" calibration.
### C. Mechanical & Installation
* **Construction:** Plug-in socket structure. The electronic module can be removed from its base without disconnecting the field wiring.
* **Mounting:** DIN Rail or surface mounting.
---
## 3. Terminal Wiring Example
Below is a generic representation of how the electronic pins are typically assigned:
```text
[ Terminal Block ]
1. Output (+)
2. Output (-)
3. Power (+) 24V DC
4. Power (-) 0V
5. Input (A) <-- RTD Wire 1
6. Input (B) <-- RTD Wire 2
7. Input (B') <-- RTD Wire 3 (Compensation)
8. Ground
```
---
## 4. Summary Table
| Feature | Specification |
| :--- | :--- |
| **Accuracy** | ±0.1% of span |
| **Response Time** | ≤ 0.5 seconds (0 – 90%) |
| **Insulation Resistance** | 100 MΩ or more (500V DC) |
| **Dielectric Strength** | 2000V AC @ 1 minute |
- ⤷
How do I calibrate the Zero and Span on the M2RTS-R-DG-R2/N?
- ⤷ What is the difference between a 2-wire and 3-wire RTD connection for this device?
- ⤷ Can the output signal be changed from Voltage to Current manually?