M2UDS-E3-R2SLASHCE
AI

The part number **M2UDS-E3-R2/CE** refers to a high-precision **Digital Panel Meter** manufactured by **M-System** (now MG CO., LTD). This specific model is part of the M2U series, designed to receive analog input signals and display them digitally while providing alarm outputs.
### 1. Model Breakdown
The suffix and prefix characters define the specific electronic capabilities of the unit:
| Code Component | Description |
| :--- | :--- |
| **M2UDS** | Model Series: Digital Panel Meter (with Alarm outputs) |
| **E3** | **Input Type:** 4 – 20 mA DC (Current Input) |
| **R2** | **Power Input:** 100 – 240V AC |
| **CE** | **Certification:** Compliant with European Safety Standards (CE Marking) |
---
### 2. Key Electronic Specifications
The internal electronics are designed for industrial process control, featuring high isolation and signal conditioning.
* **Display:** 4-digit red LED, 10.1 mm height.
* **Input Impedance:** 250 $\Omega$ (standard for 4-20mA loops).
* **Alarm Outputs:** 2-point relay contacts (SPDT).
* **Isolation:** 4-way isolation between input, output 1, output 2, and power.
* **Sampling Rate:** 500 ms (nominal).
* **Accuracy:** $\pm$0.1% of span + 1 digit.
---
### 3. Component Architecture
The device consists of three primary internal electronic stages:
#### A. Input Stage (Signal Conditioning)
This stage uses a precision shunt resistor to convert the 4-20mA current into a voltage. It includes a **Low Pass Filter** to eliminate high-frequency noise common in industrial environments.
#### B. Processing & Display
An onboard **Microprocessor** handles the Analog-to-Digital conversion (ADC). It scales the raw 4-20mA signal into user-defined engineering units (e.g., 0-100% or 0-500 Liters).
#### C. Output Stage (Relays)
The "R2" designation indicates the presence of mechanical relays. These act as "limit switches" that trigger when the input signal crosses high or low setpoints.
---
### 4. Typical Connection Diagram (General)
```text
[ Power Supply ] ------ (L) 100-240V AC (N)
|
[ 4-20mA Source ] ----(+) Input (-)
|
[ Alarm Loop 1 ] ------ Relay Contact 1
[ Alarm Loop 2 ] ------ Relay Contact 2
```
- ⤷
How do you calibrate the scaling on the M2UDS-E3 display?
- ⤷ What are the specific relay contact ratings for this model?
- ⤷ Can this unit be powered by 24V DC instead of AC?