M2VT-CD-R/N
AI

The **M2VT-CD-R/N** is a specific model within the **M2VT series** of signal conditioners manufactured by **M-System**. This device is a compact, plug-in type signal transmitter designed to convert a DC input into a standard process signal.
Below is a breakdown of the electronic components, specifications, and technical features of this unit.
---
### 1. Model Code Breakdown
The model name defines the specific electronic configuration of the device:
| Component | Code | Description |
| :--- | :--- | :--- |
| **Series** | M2VT | Mini-M series Signal Conditioner (Voltage/Current Input) |
| **Input** | C | 1 – 5V DC |
| **Output** | D | 0 – 20mA DC (Programmable/Scalable) |
| **Power Input** | R | 24V DC |
| **Standard** | /N | No special options (Standard version) |
---
### 2. Core Electronic Features
The M2VT series is known for its high-performance analog-to-digital conversion and isolation capabilities.
* **Isolation System:** It features a **3-way isolation** system (Input to Output to Power). This is achieved through high-speed optocouplers or internal transformers to prevent ground loops and protect sensitive PLCs/DCSs from electrical noise.
* **Microprocessor-Based:** Unlike pure analog transmitters, the "VT" series uses internal digital processing, allowing for precise calibration and linear conversion.
* **Front-Panel Indicators:**
* **Power LED:** Indicates the status of the internal DC-DC converter.
* **Zero/Span Adjustments:** Multi-turn potentiometers for fine-tuning the analog output.
* **A/D and D/A Converters:** High-resolution converters (typically 12 to 16-bit) ensure that the voltage input is accurately represented in the current output.
---
### 3. Technical Specifications
| Parameter | Specification |
| :--- | :--- |
| **Input Impedance** | 1 M$\Omega$ minimum |
| **Output Load Resistance** | 0 – 600 $\Omega$ |
| **Accuracy** | $\pm$0.1% of span |
| **Response Time** | $\le$ 0.5 seconds (0 – 90%) |
| **Insulation Resistance** | 100 M$\Omega$ at 500V DC |
| **Dielectric Strength** | 2000V AC @ 1 minute (Input to Output to Power) |
---
### 4. Terminal Connections
The device uses a 10-pin base socket (typically M-System's standard).
1. **Input (+/-):** Receives the 1-5V DC signal from a sensor or transducer.
2. **Output (+/-):** Provides the 0-20mA DC signal to the controller.
3. **Power (+/-):** Connects to the 24V DC supply.
---
### 5. Application Usage
The M2VT-CD-R/N is electronically engineered for:
* **Signal Level Conversion:** Changing a high-impedance voltage signal into a low-impedance current loop (0-20mA) for long-distance transmission.
* **Noise Mitigation:** Using the 2000V AC isolation to "clean" signals in industrial environments with high electromagnetic interference (EMI).
---