M2XU-R1V1-R/UL
AI

The **M2XU-R1V1-R/UL** is a specific model within the **M2XU series** of signal conditioners manufactured by **M-System**. This device is a PC-programmable, multi-input signal conditioner designed to convert various industrial input signals into a standard DC output.
---
### 1. Key Technical Specifications
The "R1V1" portion of the model number defines the power input and output configurations.
| Component | Specification | Details |
| :--- | :--- | :--- |
| **Input** | Multi-Input | Universal (DC, Thermocouple, RTD, Potentiometer, etc.) |
| **Output (V1)** | DC Output | Range: 0 – 10V DC |
| **Power Input (R)** | 24V DC | Range: 24V DC ±10% |
| **Standards** | UL/cUL | Approved for North American safety standards |
| **Programming** | PC Configurable | Parameters set via M-System’s software |
---
### 2. Electronic Architecture
The internal circuitry is designed for high precision and industrial-grade isolation.
* **Isolation Barrier:** The device features **three-way isolation** (Input to Output to Power). This prevents ground loops and protects sensitive PLC/DCS equipment from high-voltage surges on the field side.
* **A/D and D/A Conversion:** It utilizes a high-resolution Analog-to-Digital converter for the universal input and a Digital-to-Analog converter for the 0-10V output, ensuring high linearity.
* **Microprocessor Control:** The internal CPU handles linearization (especially for thermocouples and RTDs) and digital filtering to stabilize noisy signals.
* **Protection:** Includes overcurrent protection and surge suppression compliant with industrial electromagnetic compatibility (EMC) standards.
---
### 3. Connection Pinout (Typical)
While you should always consult the manual for the specific wiring diagram, the M2XU series generally follows this block structure:
| Terminal No. | Function | Description |
| :--- | :--- | :--- |
| **1 - 4** | Input | Connections for mV, V, TC, or RTD |
| **5 - 6** | Output | 0 – 10V DC (V1 configuration) |
| **7 - 8** | Power | 24V DC (R configuration) |
---
### 4. Applications
* **Temperature Monitoring:** Converting a Type K thermocouple signal to a 0-10V signal for a PLC.
* **Signal Leveling:** Converting a non-standard DC voltage from a sensor into a standard industrial range.
* **System Protection:** Providing a physical break (isolation) between field sensors and a central control system.
- ⤷
How do I configure the input type using the PC software?
- ⤷ What is the specific dielectric strength for the three-way isolation?
- ⤷ Does this model support 4-20mA output instead of 0-10V?