RTD-2412-R
AI

The **RTD-2412-R** is a high-performance, isolated DC/DC converter manufactured by **RECOM Power**. It belongs to the RTD series, which is specifically designed for industrial applications requiring dual output voltages and high isolation.
### 1. Key Technical Specifications
The following table outlines the primary electrical characteristics of the RTD-2412-R:
| Parameter | Value |
| :--- | :--- |
| **Input Voltage (Nominal)** | 24V DC |
| **Input Voltage Range** | 21.6V to 26.4V DC |
| **Output Voltage** | ±12V DC (Dual Output) |
| **Output Current** | ±84mA |
| **Power Rating** | 2 Watts |
| **Isolation Voltage** | 1kV DC (standard) |
| **Efficiency** | 80% - 84% (Typical) |
| **Package Type** | DIP14 (Dual In-line Package) |
---
### 2. Functional Components and Design
The RTD-2412-R is composed of several internal electronic stages to ensure stable power delivery:
* **Input Filter:** Typically consists of a small internal capacitor to reduce reflected ripple current.
* **Switching Topology:** Uses a high-frequency push-pull or Royer oscillator circuit to convert the DC input into an AC signal for transformer coupling.
* **Isolation Transformer:** Provides the 1kV DC galvanic isolation between the input and output circuits, protecting sensitive downstream components from input surges.
* **Rectification & Smoothing:** Internal Schottky diodes and output capacitors convert the AC back into stable ±12V DC.
---
### 3. Pin Configuration (DIP14)
The device uses a standard pinout to facilitate easy PCB integration:
| Pin Number | Function | Description |
| :--- | :--- | :--- |
| 1 | -Vin | Negative Input Voltage |
| 7 | NC | No Connection |
| 8 | Com | Common (Ground) for Output |
| 9 | +Vout | Positive 12V Output |
| 11 | -Vout | Negative 12V Output |
| 14 | +Vin | Positive Input Voltage |
---
### 4. Application Use Cases
Because this part provides **dual rail outputs (±12V)**, it is primarily used for:
1. **Operational Amplifiers (Op-Amps):** Providing the positive and negative supply rails required for precision analog signal processing.
2. **Sensor Interfaces:** Powering sensors that require symmetrical voltages to measure bipolar signals.
3. **Industrial Automation:** Breaking ground loops in complex control systems to prevent noise interference.
---
- ⤷
What are the thermal derating limits for the RTD-2412-R at high temperatures?
- ⤷ Does this model require external capacitors for low-noise operation?
- ⤷ What is the difference between the 'R' suffix and the standard RTD series?