RWS1500B12/CO2
AI

The **RWS1500B-12/CO2** is a high-reliability, industrial-grade AC-DC single-output power supply manufactured by TDK-Lambda. This specific model belongs to the RWS-B series, designed for long life and high performance in demanding environments.
### Core Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Input Voltage Range** | 85 - 265 VAC (Universal Input) |
| **Output Voltage** | 12V DC |
| **Maximum Output Current** | 125A |
| **Total Output Power** | 1500W |
| **Efficiency** | ~82% - 85% (Typical) |
| **Cooling** | Internal Variable Speed Fan |
| **Safety Certifications** | UL60950-1, EN60950-1, CE Mark |
---
### Key Internal Electronic Components & Design
The unit utilizes a complex architecture to manage high current (125A) while maintaining stability:
#### 1. Input Section (EMI & Rectification)
* **Line Filter:** Includes X and Y capacitors and common-mode chokes to suppress Electromagnetic Interference (EMI) to meet Class B standards.
* **Active PFC (Power Factor Correction):** Uses a high-frequency switching circuit to ensure the power factor is >0.95, reducing harmonic distortion on the AC line.
#### 2. DC-DC Conversion Stage
* **Primary Switching:** High-power MOSFETs or IGBTs arranged in a bridge topology to convert high-voltage DC into high-frequency AC.
* **Power Transformer:** A high-efficiency ferrite core transformer provides galvanic isolation between the input and the 12V output.
* **Secondary Rectification:** Since the output current is very high (125A), this stage uses **Synchronous Rectification** (low RDS(on) MOSFETs) instead of standard diodes to minimize heat loss and maximize efficiency.
#### 3. Control & Protection Circuits
* **Overvoltage Protection (OVP):** Shuts down the unit if the output exceeds approximately 125-145% of nominal voltage.
* **Overcurrent Protection (OCP):** Constant current limiting with automatic recovery.
* **Over-temperature Protection (OTP):** Thermal sensors on the main heatsinks trigger a shutdown if internal temperatures exceed safety limits.
---
### Understanding the suffix: `/CO2`
The `/CO2` suffix is a specific factory option regarding the physical construction and protection of the internal electronics:
* **Coating (Conformal Coating):** The internal Printed Circuit Boards (PCBs) are treated with a specialized **Conformal Coating**.
* **Purpose:** This thin chemical film protects the electronic components and traces from environmental contaminants such as:
* Dust and conductive particles.
* High humidity and moisture.
* Chemical vapors or mild corrosion.
* **Application:** This makes the `/CO2` model ideal for industrial environments where the air quality may be poor or where the device is used in outdoor enclosures.
---
### Terminal Configuration
The unit typically features heavy-duty busbars for the **12V Output** to handle the 125A load, and a screw terminal block for the **AC Input** and **Signal Pins** (Remote On/Off, DC Good signal, and Remote Sensing).
- ⤷
What are the cooling requirements and fan life expectancy for the RWS1500B series?
- ⤷ How does the 'Remote Sensing' feature work on this 12V model?
- ⤷ Can the RWS1500B-12 be connected in parallel for higher current output?