## Technical Overview: RWS1500B-15/CO2
The **RWS1500B-15/CO2** is a high-power, industrial-grade AC-DC switch-mode power supply manufactured by TDK-Lambda. This specific model is part of the RWS-B series, designed for high reliability and long life cycles.
### 1. Model Breakdown
The nomenclature reveals the core specifications:
| Segment | Meaning | Specification |
| :--- | :--- | :--- |
| **RWS** | Series Name | General Purpose Industrial |
| **1500B** | Power Rating | 1500 Watts |
| **15** | Output Voltage | 15V DC |
| **/CO2** | Option Code | **Conformal Coating** on both sides of the PCB |
---
### 2. Key Electronic Components & Features
The unit utilizes a sophisticated internal topology to manage high wattage in a compact form factor:
#### A. Input Section (Primary Side)
* **Universal AC Input:** Operates from 85V to 265V AC.
* **Active PFC (Power Factor Correction):** Uses an active circuit to ensure a power factor of 0.98 (at 100VAC) or 0.95 (at 200VAC), complying with EN61000-3-2 standards.
* **Inrush Current Limiting:** Thermistors or power relays protect internal components from surges during startup.
#### B. Conversion Stage
* **Switching Topology:** Typically utilizes a forward converter or bridge topology with high-frequency MOSFETs to minimize heat and size.
* **Transformer:** High-grade ferrite core for efficient energy transfer and galvanic isolation between primary and secondary stages.
#### C. Output Section (Secondary Side)
* **Voltage Adjustment:** Includes a built-in potentiometer allowing the 15V output to be tuned (typically ±10%).
* **Smoothing Capacitors:** High-temperature (105°C) electrolytic capacitors ensure low ripple and noise (typically 150mV peak-to-peak).
* **Bus Bars:** Heavy-duty copper terminals to handle the high current output (up to 100A).
---
### 3. Protection Circuits
The electronic control board integrates several safety mechanisms:
1. **Overcurrent Protection (OCP):** Constant current limiting with automatic recovery.
2. **Overvoltage Protection (OVP):** Shuts down the unit if the output exceeds a set threshold (approx. 115-140%) to protect the load.
3. **Over-temperature Protection (OTP):** Thermal sensors shut the unit down if internal temperatures exceed safe operating limits.
---
### 4. Special "CO2" Feature: Conformal Coating
The **/CO2** suffix is a critical electronic modification:
* **Material:** A thin polymeric film is applied to the PCB.
* **Purpose:** Protects electronic components from dust, moisture, and chemical contaminants.
* **Application:** Essential for harsh industrial environments where conductive dust or high humidity could cause short circuits or electrochemical migration.
---
### 5. Technical Specifications Summary
| Feature | Details |
| :--- | :--- |
| **Output Current** | 100 Amps |
| **Efficiency** | ~82% - 85% |
| **Cooling** | Internal forced air (Built-in Fan) |
| **Remote Sensing** | Supported (compensates for voltage drops in wiring) |
| **Isolation** | Input to Output: 3.0kVAC |
- ⤷