SVB-DB-R/CE
AI

The **SVB-DB-R/CE** is a specific electronic component typically categorized as a **Safety Main Switch** or **Emergency-Stop Disconnector**, often manufactured by companies like **Eaton (Moeller)**. These parts are critical in industrial automation for power isolation and circuit protection.
---
### 1. Technical Specifications
The following table highlights the core electronic and mechanical parameters of the SVB-DB-R/CE series:
| Feature | Specification |
| :--- | :--- |
| **Type** | Main/Emergency-Stop Switch |
| **Poles** | Usually 3-Pole (can vary by configuration) |
| **Actuator Color** | Red handle with Yellow locking ring (Safety standard) |
| **Mounting** | Rear mounting (Distribution Board/DIN rail) |
| **Protection Rating** | IP65 (Front side) |
| **Max Voltage** | 690V AC |
| **Rated Current ($I_u$)** | Typically 20A to 32A (model dependent) |
---
### 2. Core Electronic Components & Functions
The device is composed of several functional electronic and mechanical parts:
#### A. Contact Block
The internal contacts are designed for **Positive Opening Operation**. This ensures that the circuit is physically broken even if the contacts attempt to weld together under high load, meeting international safety standards (IEC/EN 60947-3).
#### B. Rotary Actuator
The red handle serves as the interface.
- **0 (OFF):** Disconnects the load from the power source.
- **1 (ON):** Completes the circuit.
- **Locking Mechanism:** Allows for Padlocking in the "OFF" position for LOTO (Lockout/Tagout) procedures.
#### C. Terminals
The part features screw-type terminals designed for high-vibration environments. These terminals are often "shrouded" to provide finger-proof protection (IP20) inside the cabinet.
---
### 3. Application Use Cases
1. **Industrial Machinery:** Used as a local disconnect to de-energize a motor for maintenance.
2. **Control Panels:** Serves as the main power entry switch for PLC cabinets.
3. **Safety Circuits:** Integrated into E-Stop loops where physical disconnection of the primary power line is required.
---
### 4. Certifications
The "CE" suffix indicates compliance with European Union health, safety, and environmental protection standards.
- **IEC/EN 60947-3:** Standard for low-voltage switchgear.
- **VDE 0660:** German safety regulation for industrial switches.
- ⤷
What is the maximum breaking capacity for the SVB-DB-R/CE series?
- ⤷ How does this switch integrate into a LOTO (Lockout/Tagout) safety program?
- ⤷ What are the differences between rear mounting and surface mounting for this part?