数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

  • TZ4H-R2R

  • AI
    The **TZ4H-R2R** is a high-performance, dual-display digital temperature controller manufactured by **Autonics**. It belongs to the TZ series, known for its high accuracy and PID control capabilities. ### 1. Model Breakdown Understanding the specific suffix is crucial for identifying its electronic capabilities: | Code Part | Description | | :--- | :--- | | **TZ4** | Model Series (DIN W96 x H48 mm size) | | **H** | High Accuracy / High Functionality | | **-R** | Control Output: **Relay Contact** (250VAC 3A) | | **2** | Power Supply: **100–240VAC** (50/60Hz) | | **R** | Sub-Output (Alarm): **Relay Output 1 + Relay Output 2** | --- ### 2. Key Electronic Specifications The internal circuitry is designed for precision and industrial stability. #### A. Input Types (Multi-Input) The device uses a universal input stage, meaning it can be programmed to accept various sensors without hardware changes: * **Thermocouple:** K, J, R, S, B, E, T, L, N, U, W, PLII. * **RTD:** Pt100Ω, JPt100Ω. * **Voltage/Current:** 1-5VDC, 0-10VDC, 4-20mA (requires external shunt resistor for mA). #### B. Output Stage (The "R" in R2R) The **Control Output** is a mechanical relay. * **Type:** SPST (1a). * **Capacity:** 250VAC 3A or 30VDC 3A (Resistive load). * **Life Expectancy:** Mechanical min. 5,000,000 operations; Electrical min. 100,000 operations. #### C. Control Method The TZ4H uses an internal microprocessor to execute two main control algorithms: 1. **PID Control:** Utilizes Auto-tuning to calculate Proportional, Integral, and Derivative constants for precise temperature maintenance. 2. **ON/OFF Control:** A simple hysteresis-based switching logic. --- ### 3. Wiring Terminal Configuration The back of the unit features a terminal block for electronic connections. Below is a typical mapping for the TZ4H series: | Terminal No. | Function | Description | | :--- | :--- | :--- | | **1 - 2** | Power Input | 100-240VAC Line/Neutral | | **3 - 5** | Control Output | Relay Contact (COM/NO) | | **6 - 8** | Alarm 1 / 2 | Sub-relay outputs for safety triggers | | **10 - 12** | Sensor Input | Pins for RTD (A, B, b) or Thermocouple (+ / -) | --- ### 4. Technical Performance Features * **Display Accuracy:** ±0.3% (Full Scale) or ±1°C (whichever is greater). * **Sampling Cycle:** 500ms. * **Dielectric Strength:** 2,000VAC 50/60Hz for 1 minute (between input terminals and power terminals). * **Insulation Resistance:** Min. 100MΩ (at 500VDC megger).
    ✨ Follow-up Questions
    • ⤷ How do I wire a 4-20mA sensor to the TZ4H-R2R?
    • ⤷ What is the difference between the TZ4H and the TCN series?
    • ⤷ How do I perform Auto-Tuning on this specific model?