The **VPS210-R** is a specialized high-voltage probe set, typically used with the Fluke ScopeMeter 190 Series. It is designed for electronic and electrical diagnostics where safety and signal integrity are paramount.
---
### ## Technical Specifications
The electronics of the VPS210-R are designed to attenuate high-voltage signals to a level safe for the oscilloscope's input circuitry while maintaining a wide frequency response.
| Feature | Specification |
| :--- | :--- |
| **Attenuation Ratio** | 10:1 |
| **Bandwidth** | 200 MHz |
| **Maximum Input Voltage** | 1000 V CAT II / 600 V CAT III |
| **Input Resistance** | 10 MΩ |
| **Input Capacitance** | 12 pF |
| **Compensation Range** | 10 pF to 22 pF |
| **Cable Length** | 1.2 Meters |
---
### ## Key Electronic Components & Design
### 1. Passive Attenuation Network
The core of the VPS210-R is a **passive resistive-capacitive (RC) voltage divider**.
* **Resistive Element:** A high-precision 9 MΩ resistor works in series with the oscilloscope’s 1 MΩ input impedance to create the 10:1 ratio.
* **Capacitive Element:** Parallel capacitors ensure that high-frequency signals bypass the resistors, preventing signal "rounding" or distortion at high speeds (up to 200 MHz).
### 2. Integrated Identification Pin
The connector end features a specific mechanical/electronic interface (often a BNC with a sensing ring). This allows compatible Fluke ScopeMeters to:
* **Auto-detect** the 10:1 attenuation.
* **Automatically adjust** the on-screen scale (e.g., if the probe sees 100V, the scope displays 100V rather than 10V).
### 3. Safety Construction
Unlike standard breadboard probes, the VPS210-R electronics are encased in reinforced insulation.
* **Double Insulation:** Protects the user from high-voltage transients.
* **Shrouded BNC:** The connector is recessed to prevent accidental contact with the common ground/shield when working with floating measurements.
### 4. Compensation Trimmer
Inside the BNC head is a small adjustable capacitor (trimmer). This allows the user to match the probe's internal capacitance to the specific input capacitance of the oscilloscope channel to ensure a flat frequency response.
---
### ## Usage Context
Because the VPS210-R is **Red** (the "-R" suffix), it is typically used for **Channel A** in a multi-channel setup, paired with the VPS210-G (Grey) for Channel B. This color-coding is essential for tracking signals in complex electronic power circuits.
- ⤷