W2AC-A13D-R2
AI

The **W2AC-A13D-R2** is a specific model of an **AC Axial Fan**, typically manufactured by brands like **CUI Devices**. It is designed for thermal management in electronic enclosures, server racks, and industrial equipment.
Below is a breakdown of its technical specifications and electronic characteristics.
### 1. Key Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Input Voltage** | 110 ~ 120 V AC |
| **Frequency** | 50/60 Hz |
| **Dimensions** | 120 x 120 x 38 mm |
| **Bearing Type** | Dual Ball Bearing |
| **Airflow** | ~95 - 108 CFM (Cubic Feet per Minute) |
| **Static Pressure** | ~0.33 - 0.38 in H2O |
| **Noise Level** | ~43 - 47 dBA |
| **Current Consumption** | ~0.21 - 0.26 A |
---
### 2. Electronic Components & Design
#### Motor Construction
The fan utilizes an **AC Shaded Pole Motor**. This is a type of single-phase induction motor. It is preferred for fans because:
* **Reliability:** No brushes to wear out.
* **Simplicity:** It does not require a starting capacitor (in most small versions).
* **Self-Starting:** The "shading coil" creates a rotating magnetic field to initiate rotation.
#### Bearing System (Dual Ball Bearing)
The "R2" suffix often denotes the bearing or revision style. Dual ball bearings are superior to sleeve bearings because:
* They can be mounted in **any orientation** (horizontal, vertical, or angled).
* They have a significantly higher **MTBF** (Mean Time Between Failures), often exceeding 70,000 hours at 40°C.
#### Protection Features
* **Impedance Protection:** The motor windings are designed to limit current flow if the fan blades are obstructed (locked rotor). This prevents the coils from overheating and catching fire.
* **Insulation Class:** Usually rated Class B or Class E, allowing for internal temperatures up to 120°C.
---
### 3. Wiring and Connection
The unit typically features a **2-terminal or 2-wire** connection system.
```json
{
"Connection": "Terminal or Lead Wire",
"Polarity": "Not applicable (AC Input)",
"Grounding": "External metal frame grounding point"
}
```
---
### 4. Application Use Cases
* **Industrial Control Panels:** To prevent PLC and VFD overheating.
* **Power Supplies:** Large-scale rectifiers and UPS systems.
* **Server Cabinets:** For high-volume air extraction.
- ⤷
What is the difference between this AC fan and a DC PWM fan?
- ⤷ How do I calculate the cooling requirements for my enclosure?
- ⤷ Does this model support speed control via a voltage regulator?