AI

The **W2AC-A31A-R2** is a specialized electronic component, typically categorized as a high-performance **AC Axial Fan** manufactured by **Sanyo Denki** (San Ace series). These fans are designed for thermal management in industrial equipment, servers, and power supplies.
---
### 1. Technical Specifications
The following table outlines the primary electronic and physical characteristics of the W2AC-A31A-R2:
| Feature | Specification |
| :--- | :--- |
| **Input Voltage** | 100V - 115V AC (Single Phase) |
| **Frequency** | 50/60 Hz |
| **Input Power** | ~18W (at 60Hz) |
| **Rated Speed** | 2,700 - 3,100 RPM |
| **Max Airflow** | ~100 - 110 CFM (Cubic Feet per Minute) |
| **Noise Level** | ~40 - 45 dB(A) |
| **Bearing Type** | Dual Ball Bearing |
| **Frame Size** | 120mm x 120mm x 38mm |
---
### 2. Key Electronic Components & Design
The internal architecture of this unit consists of several critical electronic sub-assemblies:
#### A. The Shaded Pole Motor
Unlike DC fans that use brushless controllers, this AC fan typically utilizes a **shaded-pole induction motor**.
* **Stator:** Laminations of silicon steel with copper windings.
* **Rotor:** A squirrel-cage design that reacts to the induced magnetic field.
#### B. Thermal Protection
The "R2" designation often implies specific revisions or safety features. It includes an **Impedance Protection** circuit. This ensures that if the fan blades are locked (preventing rotation), the internal windings are designed to resist burning out by limiting the current draw.
#### C. Bearing System
It utilizes a **Dual Ball Bearing** system. Electrically, this reduces friction-related heat, which prevents the lubricant from drying out, thereby extending the "Mean Time Between Failure" (MTBF) to approximately 40,000 to 70,000 hours.
---
### 3. Wiring and Connection
The W2AC-A31A-R2 usually features a simple 2-wire lead or terminal connection:
1. **Lead Wires:** Typically UL1007 AWG24 wires.
2. **Polarity:** Since it is AC, there is no strict positive/negative, but standard practice follows **Line (L)** and **Neutral (N)**.
3. **Grounding:** Many models include a grounding point on the aluminum die-cast frame to prevent ESD (Electrostatic Discharge) buildup.
---
### 4. Applications
* **Control Cabinets:** Cooling PLCs and industrial relays.
* **Medical Equipment:** Reliable heat dissipation for imaging or diagnostic tools.
* **Networking:** Cooling for 19-inch rack-mount servers.
- ⤷
What is the difference between the W2AC and the DC-powered San Ace models?
- ⤷ How does impedance protection differ from thermal fuse protection in these fans?
- ⤷ What are the mounting requirements for the 120mm frame size?