The part number **W2AC-AA4A-R2/Q** refers to a high-performance **Industrial AC Axial Fan** manufactured by **Wibond** (commonly associated with the Sanyo Denki or similar high-end thermal management series).
These fans are specifically designed for cooling electronic enclosures, server racks, and industrial machinery where high reliability and airflow are required.
---
### 1. Technical Specifications
Below are the typical technical parameters for this specific model series:
| Parameter | Specification |
| :--- | :--- |
| **Input Voltage** | 230V AC (50/60 Hz) |
| **Frame Size** | 120mm x 120mm x 38mm (Standard Square) |
| **Bearing Type** | Dual Ball Bearing (Long life) |
| **Material** | Aluminum Die-cast Frame / PBT Plastic Impeller |
| **Airflow** | ~80 - 110 CFM (Cubic Feet per Minute) |
| **Termination** | Lead Wires or Terminals (Depending on suffix) |
| **Protection** | Impedance Protected / IP Rated |
---
### 2. Breakdown of Component Parts
The "Electronic Parts" within this assembly include the following critical components:
#### A. The Induction Motor
Unlike DC fans that use a PCB with a hall-effect sensor, this AC fan uses a **Permanent Split Capacitor (PSC) motor** or a Shaded Pole motor.
* **Stator:** Laminations of silicon steel wound with copper wire.
* **Rotor:** A squirrel-cage structure integrated into the fan blade hub.
#### B. The Capacitor (The "/Q" Variant)
The suffix `/Q` often denotes a specific electrical configuration or a **Quiet/Quality** certification. In many AC fans, a small metallized polypropylene film capacitor is used to shift the phase of the current to start the motor and maintain rotation efficiency.
#### C. Thermal Protection
Most industrial AC fans include an **Internal Thermal Protector** or use **Impedance Protection**. This ensures that if the fan blades are obstructed (locked rotor), the coils will not overheat and cause a fire.
---
### 3. Applications
* **Control Cabinets:** Used to exhaust heat generated by PLCs and Inverters.
* **Telecommunications:** Cooling for base stations and rack-mounted servers.
* **Power Supplies:** Large-scale industrial UPS systems.
---
### 4. Installation Safety Note
Since this part operates at **high voltage (230VAC)**, the following must be observed:
1. **Grounding:** The aluminum frame must be properly grounded using the provided screw hole.
2. **Mounting:** Use vibration-dampening rubber gaskets to reduce noise in sensitive environments.
3. **Polarity:** AC fans are not polarity sensitive, but the direction of airflow is indicated by an arrow on the frame.
- ⤷