The **W2TS-2AC-R/N** is a specific industrial-grade signal transducer (transmitter) typically used for temperature conversion and signal conditioning in automation systems. This model is often part of the **W2 series** from manufacturers like **Watanabe Electric**.
---
### ## Technical Specifications Overview
The W2TS-2AC-R/N is designed to take a Thermocouple input and convert it into a standardized analog signal.
| Feature | Specification |
| :--- | :--- |
| **Model Type** | Thermocouple Transmitter (Thin-profile) |
| **Input Signal** | Thermocouple (e.g., K, E, J, T, B, R, S) |
| **Output Signal** | Dual Analog Outputs (R/N suffix often indicates specific output ranges) |
| **Power Supply** | AC Power (Typically 85 - 264V AC) |
| **Mounting** | DIN Rail Mounting |
| **Response Time** | High-speed response (typically < 100ms) |
---
### ### Key Electronic Components & Features
1. **Cold Junction Compensation (CJC):**
The internal circuitry includes a high-precision thermistor or temperature sensor at the terminal block. This compensates for the ambient temperature at the connection point to ensure accurate thermocouple readings.
2. **Galvanic Isolation:**
The device features **three-way isolation** (Input, Output, and Power). This prevents ground loops and protects sensitive PLC/DCS equipment from high-voltage surges on the field side.
3. **Linearization Circuitry:**
Since thermocouple voltage is non-linear relative to temperature, the internal microprocessor applies a linearization curve to ensure the output (e.g., 4-20mA or 1-5V) is proportional to the actual temperature.
4. **Burnout Protection:**
The "R/N" variants usually include a burnout feature. If the thermocouple wire breaks, the electronic output will go to a specific "Upscale" or "Downscale" limit to alert the control system of a sensor failure.
---
### ### Terminal Configuration (Standard Layout)
Most W2TS units follow a standardized wiring block:
```text
[Input Terminals] -> Thermocouple (+ / -)
[Output 1 Terminals] -> Analog Signal (e.g., 4-20mA)
[Output 2 Terminals] -> Analog Signal (Secondary monitor)
[Power Terminals] -> AC Power Input (L / N)
```
---
### ### Typical Applications
* **HVAC Systems:** Monitoring boiler temperatures.
* **Metal Processing:** Controlling furnace heat levels.
* **Food Industry:** Maintaining precise temperatures in ovens or cooling units.
* **Signal Conversion:** Converting low-millivolt thermocouple signals into long-distance current loops.
- ⤷