W2TS-2AC-R2/N
AI

The **W2TS-2AC-R2/N** is a high-precision, transducer-type signal conditioner manufactured by **M-System** (now part of MG CO., LTD.). This specific model is a **Two-wire Transmitter** designed to convert various input signals into a standard 4-20mA DC output.
---
### 1. Model Breakdown (Nomenclature)
Understanding the electronic capabilities of this part requires breaking down the product code:
| Code Segment | Meaning | Specification |
| :--- | :--- | :--- |
| **W2TS** | Model Series | Two-wire Signal Conditioner (Transmitter) |
| **2AC** | Input Type | AC Voltage/Current Input (Average Sensing) |
| **R2** | Output Type | 4 – 20 mA DC |
| **N** | Option | None (Standard configuration) |
---
### 2. Key Electronic Specifications
The internal electronics are designed for industrial durability and signal integrity.
* **Measurement Method:** Average sensing, RMS calibrated.
* **Input Impedance:**
* Current input: Approx. 50 Ω (for 1A range).
* Voltage input: Approx. 1 MΩ (for 150V range).
* **Output Signal:** 4 – 20 mA DC (Linear to the input).
* **Power Requirement:** 12 – 45 V DC (Loop powered).
* **Accuracy:** ±0.3% of span.
* **Response Time:** ≤ 0.5 seconds (0 to 90%).
---
### 3. Electronic Architecture and Components
The device consists of three primary stages:
#### A. Input Conditioning Stage
The AC input signal is passed through a transformer or a shunt resistor to scale the voltage/current down to electronic levels. This stage provides **galvanic isolation** between the high-voltage AC source and the low-voltage DC loop.
#### B. Conversion Stage
The AC signal is rectified and filtered. Because this is an "Average Sensing" model, it uses a precision rectifier circuit to find the average value of the AC waveform, which is then calibrated to represent the Root Mean Square (RMS) value for a pure sine wave.
#### C. Loop-Powered Output Stage
The device regulates the current flow from the external power supply (typically 24V DC). It acts as a variable resistor, modulating the current between 4mA and 20mA based on the processed input signal.
---
### 4. Connection Diagram (Standard Two-Wire)
The W2TS-2AC-R2/N is connected in series with the power supply and the load (e.g., a PLC input).
```mermaid
graph LR
A[AC Source] --> B[W2TS-2AC]
B --> C[DC Power Supply +]
C --> D[Load/PLC Input]
D --> B
```
---
### 5. Installation and Safety
* **Mounting:** Designed for M3.5 screw terminal connection, often DIN rail or wall-mounted.
* **Isolation:** Usually provides 2000V AC isolation between input and output.
* **Environment:** Operating temperature range is typically -5°C to +55°C.
---
- ⤷What is the difference between average sensing and true RMS sensing in these transmitters?
- ⤷ How do I calculate the maximum load resistance for the 4-20mA loop?
- ⤷ Can the W2TS-2AC-R2/N handle frequency variations in the AC input?