Specifi cations
Contact Type: Reed/magnet contact
NC (Normally Closed): Contact open with air fl ow
NO (Normally Open): Contact closed with air fl ow
Switching Threshold of Air Flow Speed: >8.2 ft/s
2.5 m/s)
Hysteresis: 3.3 ft/s (1m/s) - fi xed
Contact Resistance Incl. Wire: 370m (1214”)
Service Life: >100,000 cycles
Maximum Switching Capacity: 10W (resistive load)
Maximum Switching Voltage: NC - AC/DC 240V
NO - DC 60V
Maximum Switching Current: NC - DC 500mA
NO - DC 170mA
perpendicular to air fl ow
Operating Temperature: -20 to 50°C (-4 to 122°F)
Storage Temperature: -20 to 80°C (-4 to 176°F)
Housing: Plastic, UL 94HB, black
Dimensions: 34 x 17.5 x 7.5mm (1.3 x 0.7 x 0.3”)
Protection Type: NEMA 1 (IP 20)
Agency Approvals: CE
RoHS Compliant
protective plastic grill
Mounting Position: Air-flow monitoring opening
Connection: 2 x single strand AWG26, length 500mm
(20”), tip of stranded wire stripped/tinned 5mm (0/20”)
NC version (black wires), NO version (blue wires)
Mounting: Attachment clamp and/or clip, or integrated in
|