MSP432P411VIPZ 数据表(PDF) 72 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
MSP432P411VIPZ 数据表(HTML) 72 Page - Texas Instruments |
|
72 / 212 page ![]() Ambient Temperature (°C) -40 -20 0 20 40 60 80 100 600 625 650 675 700 725 750 775 800 825 850 875 D020 72 MSP432P4111, MSP432P4011, MSP432P411Y MSP432P401Y, MSP432P411V, MSP432P401V SLASEA0A – DECEMBER 2017 – REVISED FEBRUARY 2018 www.ti.com Submit Documentation Feedback Product Folder Links: MSP432P4111 MSP432P4011 MSP432P411Y MSP432P401Y MSP432P411V MSP432P401V Specifications Copyright © 2017–2018, Texas Instruments Incorporated Table 5-31 lists the characteristics of the temperature sensor and built-in V1/2. (1) The temperature sensor offset can be as much as ±35°C. TI recommends a single-point calibration to minimize the offset error of the built-in temperature sensor. (2) The TLV structure contains calibration values for 30°C ±3°C and 85°C ±3°C for each of the available reference voltage levels. The sensor voltage can be computed as VSENSE = TCSENSOR × (Temperature,°C) + VSENSOR, where TCSENSOR and VSENSOR can be computed from the calibration values for higher accuracy. (3) The typical equivalent impedance of the sensor is 250 kΩ. The sample time required includes the sensor-on time tSENSOR(on). (4) The on-time tV1/2 (on) is included in the sampling time tV1/2 (sample). No additional on time is needed. Table 5-31. Precision ADC Temperature Sensor and Built-In V1/2 over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) PARAMETER TEST CONDITIONS VCC MIN TYP MAX UNIT VSENSOR Temperature sensor voltage(1) (2) (see Figure 5-29) ADC14ON = 1, ADC14TCMAP = 1, TA = 0°C 685 mV TCSENSOR Change in voltage with temperature(2) ADC14ON = 1, ADC14TCMAP = 1 1.9 mV/°C tSENSOR (sample) Sample time required if ADCTCMAP = 1 and channel (MAX – 1) is selected(3) ADC14ON = 1, ADC14TCMAP = 1, Error of conversion result ≤ 1 LSB 5 µs V1/2 AVCC voltage divider for ADC14BATMAP = 1 on MAX input channel ADC14ON = 1, ADC14BATMAP = 1 48% 50% 52% tV 1/2 (sample) Sample time required if ADC14BATMAP = 1 and channel MAX is selected(4) ADC14ON = 1, ADC14BMAP = 1 1 µs Figure 5-29. Typical Temperature Sensor Voltage |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |