| 数据搜索系统,热门电子元器件搜索 |
|
MLX90805S 数据表(PDF) 7 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
MLX90805S 数据表(HTML) 7 Page - List of Unclassifed Manufacturers |
|
7 / 13 page ![]() MLX902xx Name of Sensor Rev Y.X 22/Aug/98 Page 7 MLX90805 Intelligent Triac Controller MLX90805 Intelligent Triac Controller Page 7 Rev 1.2 17/May/00 Maximum phase angle Independent of the phase angle definitions in the ROM table, a maximum phase angle can be defined. This is the phase angle that will be applied immedi- ately after the power on sequence, and is therefore the first phase angle in the soft start sequence. This maximum phase angle is defined in MIN[9:0] with the formula: MIN[9:0] = Tini * 2 * Fmains - 10 With: Tini = the initial phase angle (in msec) Fmains = frequency of the mains (in Hz) Default value: Tini = 7 msec and Fmains = 50Hz, thus MIN[9:0] is 690. Soft start time duration There are 5 bits ATN[4:0] used to define the duration of the soft start time. The bits can be calculated with following formula: Ts = ((Tini – Tmin) * ATTN ) / 62.5 With: Ts = the duration of the soft start (in sec.) Tini = the initial phase angle defined by MIN[9:0] (in msec) Tmin = the phase angle corresponding to the value in the highest ROM address (in msec) ATTN = bin2dec(ATN[4:0]+1), a value between 2 and 32. Default value: Tini = 8msec, Tmin = 1.84 msec, ATTN = 32, thus Ts = 3.15 sec. Firing pulse duration The duration of the firing pulses can be defined by the bits DUTS[1:0] according to following table. The default value is 20 usec. DUTS1 DUTS0 Duration in µS 0 0 320 0 1 80 1 0 40 1 1 20 Enable Retriggering With bit RTRIG set to 1, triac retriggering is enabled. The retriggering circuit checks whether the triac is ON, if not additional firing pulses are generated every 20us (with respect to the end of the previous firing pulse) until firing of the triac. With bit RTRIG set to 0, triac retriggering is disabled. For each triac firing two pulses are generated with a delay of 20 usec (with respect to the end of the previous firing pulse). The default value is triggering enabled. Retriggering Mask With the option MINA[3:0] it is possible to define a zone at the end of each half cycle of the mains voltage, where it is impossible to generate retriggering pulses. This has two purposes: With some (non inductive) loads the current can become quite small at the end of each half cycle. This can eventually activate the retriggering circuit which will unnecessarily generate additional pulses thus increasing the current consumption. When generating a retriggering pulse just before the zero crossing, this pulse could overlap to the next half period. With some (non inductive) loads this can lead to false triggering at full power and must be avoided. The bits MINA[3:0] are defined according to the following formula: Tmina * 2 * Fmains = MINA[3:0] * 64 With: Tmina = the phase angle from which retriggering is prohibited (in msec) Fmains = frequency of the mains (in Hz) Default value: MINA[3:0]=1101'b=13'd and Fmain = 50Hz, this means that retriggering is prohibited at 8.32ms. Soft start only Function regulator See page 8 2-wire or 3-wire potentiometer connection. See pages 9 and 10 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |