| 数据搜索系统,热门电子元器件搜索 |
|
AM29PDL128G80 数据表(PDF) 21 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
AM29PDL128G80 数据表(HTML) 21 Page - SPANSION |
|
21 / 69 page ![]() 20 Am29PDL128G July 29, 2002 P R E L I M I NARY Table 6. SecSi Sector Addresses Autoselect Mode The autoselect mode provides manufacturer and de- vice identification, and sector protection verification, through identifier codes output on DQ7–DQ0. This mode is primarily intended for programming equip- ment to automatically match a device to be pro- grammed with its co rresponding programm ing algorithm. However, the autoselect codes can also be accessed in-system through the command register. When using programming equipment, the autoselect mode requires V ID on address pin A9. Address pins must be as shown in Table 7. In addition, when verify- ing sector protection, the sector address must appear on the appropriate highest order address bits (see Table 5). Table 7 shows the remaining address bits that are don’t care. When all necessary bits have been set as required, the programming equipment may then read the corresponding identifier code on DQ7–DQ0. However, the autoselect codes can also be accessed in-system through the command register, for instances when the device is erased or programmed in a system without access to high voltage on the A9 pin. The command sequence is illustrated in Tables 14 and 16. Note that if a Bank Address (BA) on address bits A21, A20, and A19 is asserted during the third write cycle of the autoselect command, the host system can read autoselect data that bank and then immediately read array data from the other bank, without exiting the au- toselect mode. To access the autoselect codes in-system, the host system can issue the autoselect command via the command register, as shown in Tables 14 and 16. This method does not require V ID. Refer to the Autoselect Command Sequence section for more information. Table 7. Autoselect Codes (High Voltage Method) Legend: L = Logic Low = V IL, H = Logic High = VIH, BA = Bank Address, SA = Sector Address, X = Don’t care. Note: The autoselect codes may also be accessed in-system via command sequences. Device Sector Size (x32) Address Range (x16) Address Range Am29PDL128G 128 words/64 double words 000000h–00003Fh 000000h–00007Fh Description CE# OE# WE# A21 to A11 A10 A9 A8 A7 A6 A5 to A4 A3 A2 A1 A0 DQ31 to DQ8 (Word/Double Word) DQ7 to DQ0 Manufacturer ID: AMD LL H X X V ID X X L X L L L L 000000h 01h Read Cycle 1 LL H X X V ID XL L L LL L H 22h/ 222222h 7Eh Read Cycle 2 LH H H L 22h/ 222222h 0Dh Read Cycle 3 LH H H H 22h/ 222222h 00h Sector Protection Verification LL H SA X V ID XL L H H L H L 00h/ 000000h 01h (protected), 00h (unprotected) SecSi Indicator Bit (DQ7) LL H X X V ID XX L X L L H H 00h/ 000000h 80h (factory locked), 00h (not factory locked) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |