| 数据搜索系统,热门电子元器件搜索 |
|
AM29PL320DB70RWPI 数据表(PDF) 22 Page - SPANSION |
|
|
|||||||||||||||||||||||||||||
AM29PL320DB70RWPI 数据表(HTML) 22 Page - SPANSION |
|
22 / 50 page ![]() 20 Am29PL320D October 2, 2003 Erase Suspend mode, the system may once again read array data with the same exception. See “Erase Suspend/Erase Resume Commands” for more infor- mation on this mode. The system must issue the reset command to re-en- able the device for reading array data if DQ5 goes high, or while in the autoselect mode. See the “Reset Command” section, next. See also “Requirements for Reading Array Data” in the “Device Bus Operations” section for more information. The Read Operations table provides the read parame- ters, and Figure 13 shows the timing diagram. Reset Command Writing the reset command to the device resets the de- vice to reading array data. Address bits are don’t care for this command. The reset command may be written between the se- quence cycles in an erase command sequence before erasing begins. This resets the device to reading array data. Once erasure begins, however, the device ig- nores reset commands until the operation is complete. The reset command may be written between the se- quence cycles in a program command sequence before programming begins. This resets the device to reading array data (also applies to programming in Erase Suspend mode). Once programming begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the se- quence cycles in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to reading array data (also applies to autoselect during Erase Suspend). If DQ5 goes high during a program or erase operation, writing the reset command returns the device to read- ing array data (also applies during Erase Suspend). Autoselect Command Sequence The autoselect command sequence allows the host system to access the manufacturer and devices codes, and determine whether or not a sector is protected. Table 13 shows the address and data requirements. The autoselect command sequence is initiated by writ- ing two unlock cycles, followed by the autoselect command. The device then enters the autoselect mode, and the system may read any number of autoselect codes without reinitiating the command sequence. Tables 13 and 14 show the address and data require- ments for the command sequence. To determine sec- tor protection information, the system must write to the appropriate sector address (SA). Tables 4 and 6 show the address range associated with each sector. The system must write the reset command to exit the autoselect mode and return to reading array data. Enter SecSi ™ Sector/Exit SecSi Sector Command Sequence The SecSi Sector region provides a secured data area containing a random, eight-word (or four double word) electronic serial number (ESN). The system can ac- cess the SecSi Sector region by issuing the three- cycle Enter SecSi Sector command sequence. The device continues to access the SecSi Sector region until the system issues the four-cycle Exit SecSi Sec- tor command sequence. The Exit SecSi Sector com- m a nd s eque nc e ret u r n s the dev ic e to nor mal operation. Table 13 shows the address and data re- quirements for both command sequences. See also “Sec Si ™ (S ecu red Silic on ) Sec tor Fla sh Memory Region” for further information. Word/Double Word Program Command Sequence The system may program the device by word or double word, depending on the state of the WORD# input. Programming is a four-bus-cycle operation. The pro- gram command sequence is initiated by writing two unlock write cycles, followed by the program set-up command. The program address and data are written next, which in turn initiate the Embedded Program al- gorithm. The system is not required to provide further controls or timings. The device automatically gener- ates the program pulses and verifies the programmed cell margin. Table 13 shows the address and data re- quirements for the program command sequence. When the Embedded Program algorithm is complete, the device then returns to reading array data and ad- dresses are no longer latched. The system can determine the status of the program operation by using DQ7 or DQ6. See “Write Operation Status” for informa- tion on these status bits. Any commands written to the device during the Em- bedded Program Algorithm are ignored. The Program command sequence should be reinitiated once the de- vice has reset to reading array data, to ensure data integrity. Programming is allowed in any sequence and across sector boundaries. A bit cannot be programmed from a “0” back to a “1”. Attempting to do so may halt the operation and set DQ5 to “1,” or cause the Data# Polling algorithm to indicate the operation was successful. However, a succeeding read will show that the data is still “0”. Only erase operations can convert a “0” to a “1”. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |