数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

LRTBC9TP 数据表(PDF) 25 Page - OSRAM GmbH

部件名 LRTBC9TP
功能描述  ceramic package for RGB-Displays with diffused silicon resin
PDF  25 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  OSRAM [OSRAM GmbH]
网页  http://www.osram.com
标志 OSRAM - OSRAM GmbH

LRTBC9TP 数据表(HTML) 25 Page - OSRAM GmbH

Back Button LRTBC9TP Datasheet HTML 17Page - OSRAM GmbH LRTBC9TP Datasheet HTML 18Page - OSRAM GmbH LRTBC9TP Datasheet HTML 19Page - OSRAM GmbH LRTBC9TP Datasheet HTML 20Page - OSRAM GmbH LRTBC9TP Datasheet HTML 21Page - OSRAM GmbH LRTBC9TP Datasheet HTML 22Page - OSRAM GmbH LRTBC9TP Datasheet HTML 23Page - OSRAM GmbH LRTBC9TP Datasheet HTML 24Page - OSRAM GmbH LRTBC9TP Datasheet HTML 25Page - OSRAM GmbH  
Zoom Inzoom in Zoom Outzoom out
 25 / 25 page
background image
LRTB C9TP
2014-01-28
25
Fußnoten:
1)
Helligkeitswerte werden während eines Strompulses einer
typischen
Dauer
von
25
ms,
mit
einer
internen
Reproduzierbarkeit von +/- 8 % und einer erweiterten
Messunsicherheit von +/- 11 % gemessen (gemäß GUM mit
Erweiterungsfaktor k = 3).
2)
Die LED kann kurzzeitig in Sperrichtung betrieben werden.
3)
Die dominante Wellenlänge wird während eines Strompulses
einer typischen Dauer von 25 ms, mit einer internen
Reproduzierbarkeit von +/- 0,5 nm und einer erweiterten
Messunsicherheit von +/- 1 nm gemessen (gemäß GUM mit
Erweiterungsfaktor k = 3).
4)
Vorwärtsspannungen werden während eines Strompulses
einer
typischen
Dauer
von
8
ms,
mit
einer
internen
Reproduzierbarkeit von +/- 0,05 V und einer erweiterten
Messunsicherheit von +/- 0,1 V gemessen (gemäß GUM mit
Erweiterungsfaktor k=3)
5)
Wegen
der
besonderen
Prozessbedingungen
bei
der
Herstellung von LED können typische oder abgeleitete
technische
Parameter
nur
aufgrund
statistischer
Werte
wiedergegeben
werden.
Diese
stimmen
nicht
notwendigerweise mit den Werten jedes einzelnen Produktes
überein, dessen Werte sich von typischen und abgeleiteten
Werten oder typischen Kennlinien unterscheiden können. Falls
erforderlich,
z.B.
aufgrund
technischer
Verbesserungen,
werden diese typischen Werte ohne weitere Ankündigung
geändert.
6)
Maße werden wie folgt angegeben: mm (inch)
7)
Gehäuse hält TTW-Löthitze aus nach CECC 00802
8)
Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden
Apparaten oder Systemen eingesetzt wird und dessen Defekt
voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden
Apparates oder Systems führen wird oder die Sicherheit oder
Effektivität dieses Apparates oder Systems beeinträchtigt.
9)
Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper
oder
(b) für die Lebenserhaltung bestimmt.
Falls sie versagen, kann davon ausgegangen werden, dass die
Gesundheit und das Leben des Patienten in Gefahr ist.
Published by
OSRAM Opto Semiconductors GmbH
Leibnizstrasse 4, D-93055 Regensburg
www.osram-os.com
© All Rights Reserved.
Remarks:
1)
Brightness values are measured during a current pulse of
typical 25 ms, with an internal reproducibility of +/- 8 % and an
expanded uncertainty of +/- 11 % (acc. to GUM with a coverage
factor of k = 3).
2)
Driving the LED in reverse direction is suitable for short term
application.
3)
The dominant wavelength is measured at a current pulse of
typical 25 ms, with an internal reproducibility of +/- 0,5 nm and
an
expanded uncertainty of +/- 1 nm (acc. to GUM with a
coverage factor of k=3).
4)
The forward voltage is measured during a current pulse of
typical 8 ms, with an internal reproducibility of +/- 0,05 V and an
expanded uncertainty of +/- 0,1 V (acc. to GUM with a coverage
factor of k=3).
5)
Due to the special conditions of the manufacturing processes of
LED, the typical data or calculated correlations of technical
parameters can only reflect statistical figures. These do not
necessarily correspond to the actual parameters of each single
product, which could differ from the typical data and calculated
correlations or the typical characteristic line. If requested, e.g.
because of technical improvements, these typ. data will be
changed without any further notice.
6)
Dimensions are specified as follows: mm (inch)
7)
Package able to withstand TTW-soldering heat acc. to
CECC 00802
8)
A critical component is a component used in a life-support
device or system whose failure can reasonably be expected to
cause the failure of that life-support device or system, or to
affect its safety or the effectiveness of that device or system.
9)
Life support devices or systems are intended
(a) to be implanted in the human body,
or
(b) to support and/or maintain and sustain human life. If they
fail, it is reasonable to assume that the health and the life of the
user may be endangered.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com