13 / 16 page ![]() MP4051—NON-ISOLATED OFFLINE LED CONTROLLER WITH ACTIVE PFC MP4051 Rev. 1.01 www.MonolithicPower.com 13 1/21/2014 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2014 MPS. All Rights Reserved. The OCP setting point can be calculated as: ⋅⋅ − = + OCP2 PRI_ OCP CS D OCP1 OCP2 R IR V 0.6V RR IPRI_OCP—Primary-side over current protection point. For some applications, the inductor value is very small, the minimal-off time feature could make the system work in DCM at the zero-crossing of the BUS voltage. To improve the OCP function in this condition, please remove CZCD and reduce the value of RZCD1 and RZCD2 proportionally. Thermal Shut Down To prevent from any lethal thermal damage, when the inner temperature exceeds OTP threshold, the MP4051 shuts down switching cycle and latched until VCC drop below UVLO and restart again. Design Example For the design example, please refer to MPS application note AN0xx for the detailed design procedure and information. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|