CME0505SPC 数据表(PDF) 2 Page - Murata Power Solutions Inc.

部件名 CME0505SPC
功能描述  Isolated 0.75W Single Output Isolated DC/DC Converters
PDF  11 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  MURATA-PS [Murata Power Solutions Inc.]
网页  http://www.murata-ps.com
标志 MURATA-PS - Murata Power Solutions Inc.

CME0505SPC 数据表(HTML) 2 Page - Murata Power Solutions Inc.

  CME0505SPC Datasheet HTML 1Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 2Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 3Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 4Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 5Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 6Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 7Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 8Page - Murata Power Solutions Inc. CME0505SPC Datasheet HTML 9Page - Murata Power Solutions Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 11 page
background image
CME Series
Isolated 0.75W Single Output Isolated DC/DC Converters
KDC_CME.B01 Page 2 of 11
www.murata-ps.com/support
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Typ.
Max.
Units
Specification
All output types
-40
85
°C
Storage
-50
130
Case temperature rise above
ambient
3.3V & 5V output types
41
12V output types
32
Short circuit types (DIP)
23
Short circuit types (SIP)
24
Cooling
Free air convection
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions CME series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second for C versions and 3kVDC for 1
second for 3C versions.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The CME has been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The CME series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The CME series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85ºC and/or case temperature
limit of 100ºC for CMExxxxxC, 130ºC for CMExxxxS3C. Case temperature measured on the face opposite the pins.
The CME series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
CME03xxS3C: 0.9A
CME05xxxxC: 0.5A
All fuses should be UL recognized and rated to 125V.
File number E151252 applies.



Html Pages

1 2 3 4 5 6 7 8 9 10 11


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com