4 / 6 page ![]() ®® ADS-117 4 CALIBRATION PROCEDURE 1. Connect the converter per Figure 3, Figure 4, and Table 1 for the appropriate input range. Apply a pulse of 150 nanoseconds to the START CONVERT input (pin 16) at a rate of 250kHz. This rate is chosen to reduce flicker if LED’s are used on the outputs for calibration purposes. 2. Zero Adjustments Apply a precision voltage reference source between the amplifier’s analog input and ground. Adjust the output of the reference source per Table 2. For unipolar, adjust the zero trimming potentiometer so that the output code flickers equally between 0000 0000 0000 and 0000 0000 0001 with the pin 18 tied high (straight binary) or between 1111 1111 1111 and 1111 1111 1110 with the pin 18 tied low (comple- mentary binary). For bipolar operation, adjust the potentiometer such that the code flickers equally between 1000 0000 0000 and 1000 0000 0001 with pin 18 tied high (offset binary) or between 0111 1111 1111 and 0111 1111 1110 with pin 18 tied low (complementary offset binary). 3. Full-Scale Adjustment Set the output of the voltage reference used in step 2 to the value shown in Table 1. Adjust the gain trimming potentiom- eter so that the output code flickers equally between 1111 1111 1110 and 1111 1111 1111 for pin 18 tied high or between 0000 0000 0001 and 0000 0000 0000 for pin 18 tied low. 4. To confirm proper operation of the device, vary the preci- sion reference voltage source to obtain the output coding listed in Table 3. To Pin19 of ADS-117 –15V +15V For values of R1 and R2 refer to Table 1. R2 R1 5k Ω 50 Ω 10k Ω ZERO/ OFFSET ADJUST SIGNAL INPUT GAIN ADJUST 5k Ω ➀ ➀ ➀ Figure 3. ADS-117 Connection Diagram Table 1. Input Connections (using external calibration) INPUT RANGE R1 R2 UNIT 0 +10V, ±5 2 2 k Ω 0 to 5V, ±2.5V 2 6 k Ω 0 to +2.5V, ±1.25V 2 14 k Ω Table 2. Zero and Gain Adjustments Input Zero Adjust Gain Adjust Range +1/2 LSB +FS – 1 1/2 LSB 0 to +10V +1.22mV +9.9963V ±5V +1.22mV +4.9963V Figure 4. Optional Calibration Circuit 0.1µF 4.7µF 13 14 ADS-117 19 16 12 11 10 9 8 7 6 5 4 3 2 1 15 17 BIT 1 (MSB) BIT 2 BIT 3 BIT 4 BIT 5 BIT 6 BIT 7 BIT 8 BIT 9 BIT 10 BIT 11 BIT 12 (LSB) EOC ENABLE (1-12) ANALOG INPUT START CONVERT + +5V –15V +15V + + 0.1µF 4.7µF 23 22 0.1µF 4.7µF 24 20 COMP BIN 0.1µF + 4.7µF 21 +10V REF. UNIPOLAR OPERATION 18 +5V NOTE: BIPOLAR INPUT For unipolar operation, ground pin 20. For bipolar operation, connect pin 20 to pin 21. Always bypass pin 21 as shown for both unipolar and bipolar operation. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |