6 / 9 page ![]() UT3227 Preliminary CMOS IC UNISONICTECHNOLOGIESCO.,LTD 6 of 9 www.unisonic.com.tw QW-R103-146.a DETAILED DESCRIPTION Charge-Pump Voltage Converter The UTC UT3227 consists of a regulated dual charge pumps that provide output voltages of +5.5V and -5.5V, regardless of the input voltage (VCC) changing from +3.0V to +5.5V. The charge pumps operate in a discontinuous mode: if the output voltages are less than 5.5V, the charge pumps are enabled; if the output voltages exceed 5.5V, the charge pumps are disabled. Each charge pump requires a flying capacitor (C1, C2) and a reservoir capacitor (C3, C4) to generate the V+ and V- supplies, refer to application circuit. RS-232 Transmitter UTC UT3227’s transmitter is inverting level translators that convert CMOS-logic levels to 5.0V EIA/TIA-232 levels. They guarantee a 1Mbps data rate with worst-case loads of 3kΩ in parallel with 1000pF, providing compatibility with PC-to-PC communication software. Transmitter can be paralleled to drive multiple receivers or mouse. When FORCEOFF is driven to ground, or shutdown circuitry senses invalid voltage levels at receiver input, the transmitter is disabled and the output are forced into a high-impedance state. RS-232 Receiver The UTC UT3227’s receiver convert RS-232 signals to CMOS-logic output levels. The receiver has one inverting three-state output. In shutdown or in autoshutdown, the UT3227’s receiver is active. The UTC UT3227 features an INVALID output that is enabled low when no valid RS-232 voltage levels have been detected on receiver input. Because INVALID indicates the receiver input’s condition, it is independent of FORCEON and FORCEOFF states Table 1. INVALID Control Truth Table RS-232 SIGNAL PRESENT AT RECEIVER INPUT INVALID OUTPUT YES High NO Low Shutdown Function A 1µA supply current is achieved with shutdown feature, which operates when FORCEON is low and FORCEOFF is high. When the UTC UT3227 do not sense a valid signal transition on any receiver and transmitter input for 30sec, the on-board charge pumps are shutdown, reducing supply current to 1µA. This occurs if the RS-232 cable is disconnected or the connected peripheral transmitters are turned off. The system turns on again when a valid transition is applied to any RS-232 receiver or transmitter input (Table 2). As a result, the system saves power without changes to the existing BIOS or operating system. INVALID indicates the receiver inputs’ condition, when using shutdown function, the INVALID output is high when the device is on and low when the device is shut down. Table 2. Shutdown Logic Control Truth Table OPERATION STATUS FORCEOFF INPUT FORCEON INPUT Valid signal at Transmitter or Receiver T1OUT Normal Operation (AutoShutdown Disable) H H X Active Normal Operation (AutoShutdown) H L YES Active Normal Operation (AutoShutdown) H L NO High-Z Shutdown L X X High-Z |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |