2 / 5 page ![]() 2 Technical Data 4132 Effective April 2016 DR1030 Shielded power inductors www.eaton.com/elx Product Specifications Part Number5 OCL1 (μH) ±30% I rms 2 (A) I sat 3 (A) DCR (mΩ) typical @ 20°C DCR (mΩ) maximum @ 20°C K-factor4 DR1030-1R1-R 1.1 7.0 9.5 6.5 7.9 22 DR1030-1R8-R 1.9 5.9 7.4 9.1 11.0 17 DR1030-2R8-R 2.8 5.1 6.08 12.1 14.5 14 DR1030-3R9-R 4.0 4.3 5.1 16.4 20.0 12 DR1030-5R2-R 5.2 3.7 4.75 22.9 27.5 10 DR1030-6R8-R 6.8 3.5 3.9 24.9 30.0 9 DR1030-8R2-R 8.4 3.3 3.54 28.4 34.1 8 DR1030-100-R 10.4 2.8 3.18 40.2 48.0 7 DR1030-150-R 14.8 2.3 2.66 57.3 68.8 6 DR1030-220-R 22.8 1.8 2.19 95.5 115 5 DR1030-330-R 32.4 1.6 1.81 114 136 4 DR1030-470-R 47.9 1.3 1.52 167 200 3.4 DR1030-680-R 67 1.1 1.24 253 304 2.9 DR1030-820-R 82 1.0 1.14 332 382 2.6 DR1030-101-R 100 0.86 1.05 375 450 2.4 DR1030-121-R 119 0.80 0.95 523 602 1.9 DR1030-151-R 155 0.68 0.86 590 700 1.4 1. Open Circuit Inductance (OCL) Test Parameters: 100 kHz, 0.1 Vrms, 0.0 Adc, +25 °C 2. Irms: DC current for an approximate temperature rise of 40 °C without core loss. Derating is necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other heat generating components will affect the temperature rise. It is recommended that the temperature of the part not exceed 125 °C under worst case operating conditions verified in the end application. 3. Isat: Peak current for approximately 35% rolloff @ +25 °C 4. K-factor: K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L * ΔI. Bp-p: (mT), K: (K-factor from table), L: (Inductance in μH), ΔI (Peak to peak ripple current in Amps).. 5. Part Number Definition: DR1030-xxx-R DR1030 = Product code and size -xxx= inductance value in μH, R= decimal point, If no R is present then last character equals number of zeros -R suffix = RoHS compliant Part marking: inductance value in uH. R = decimal point. If no R is present then last character equals number of zeroes. wwlly = date code, R = revision level Do not route traces or vias underneath the inductor Dimensions (mm) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |