| 数据搜索系统,热门电子元器件搜索 |
|
DR1040-101-R 数据表(PDF) 2 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
DR1040-101-R 数据表(HTML) 2 Page - Eaton All Rights Reserved. |
|
2 / 5 page ![]() 2 Technical Data 4147 Effective April 2016 DR1040 Shielded power inductors www.eaton.com/elx Product Specifications Part Number5 OCL1 (μH) ±30% I rms 2 (A) I sat 2 (A) DCR (mΩ) typical @ 20°C DCR (mΩ) maximum @ 20°C K-factor4 DR1040-1R5-R 1.35 6.5 10 6.0 8.1 15.5 DR1040-2R5-R 2.4 6.1 7.8 7.0 9.0 12.0 DR1040-3R8-R 3.6 5.5 6.4 9.6 13 9.9 DR1040-5R2-R 5.2 5.4 5.5 14 17 8.3 DR1040-7R0-R 6.8 4.5 4.8 17 20 7.2 DR1040-8R2-R 8.1 3.98 4.6 24 29 6.4 DR1040-100-R 9.6 3.8 4.4 26 35 5.7 DR1040-150-R 14.9 3.1 3.6 37 50 4.7 DR1040-220-R 21.1 ±20% 2.5 2.9 54 73 4.0 DR1040-330-R 32.6 2.2 2.45 69 93 3.3 DR1040-470-R 45.8 1.9 2.1 95 128 2.8 DR1040-680-R 65.3 1.42 1.65 152 183 2.3 DR1040-820-R 87 1.29 1.47 214 260 2.0 DR1040-101-R 101 1.25 1.35 225 304 1.9 DR1040-151-R 148 0.85 1.15 356 430 1.6 DR1040-221-R 216 0.70 0.92 530 640 1.3 DR1040-331-R 323 0.52 0.70 810 1090 1.0 1. Open Circuit Inductance (OCL) Test Parameters: 100 kHz, 0.25 Vrms, 0.0 Adc, +25 ºC 2. Irms: DC current for an approximate temperature rise of 30 ºC without core loss. Derating is necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other heat generating components will affect the temperature rise. It is recommended that the temperature of the part not exceed 125 ºC under worst case operating conditions verified in the end application. 3. Isat: Peak current for approximately 35% rolloff @ +25 ºC 4. K-factor: K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L * ΔI. Bp-p: (mT), K: (K-factor from table), L: (Inductance in μH), ΔI (Peak to peak ripple current in Amps).. 5. Part Number Definition: DR1040-xxx-R DR1040 = Product code and size -xxx= inductance value in μH, R= decimal point, If no R is present then last character equals number of zeros -R suffix = RoHS compliant Dimensions (mm) Part marking: inductance value in uH. R = decimal point. If no R is present then last character equals number of zeroes. wwlly = date code, R = revision level Do not route traces or vias underneath the inductor |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |