| 数据搜索系统,热门电子元器件搜索 |
|
FP1008R7-R180-R 数据表(PDF) 2 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
FP1008R7-R180-R 数据表(HTML) 2 Page - Eaton All Rights Reserved. |
|
2 / 6 page ![]() 2 Technical Data 10629 Effective December 2016 FP1008R7 High frequency, high current power inductors www.eaton.com/electronics Product specifications Part Number8 OCL1 (nH) ±10% FLL2 (nH) minimum I rms 3 (A) I sat1 4 (A) I sat2 5 (A) I sat3 6 (A) DCR (mΩ) maximum @ 20°C K-factor7 FP1008R7-R100-R 100 72 72 100 90 84 0.120 361 FP1008R7-R120-R 120 86 72 90 75 70 0.120 361 FP1008R7-R150-R 150 108 72 72 60 56 0.120 361 FP1008R7-R180-R 180 130 72 60 50 46 0.120 361 1. Open Circuit Inductance (OCL) Test Parameters: 100 kHz, 0.1 Vrms, 0.0 Adc, +25 °C 2. Full Load Inductance (FLL) Test Parameters: 100 kHz, 0.1 Vrms, I sat1, +25 °C 3. I rms: DC current for an approximate temperature rise of 40 °C without core loss. Derating is necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of other heat generating components will affect the temperature rise. It is recommended that the temperature of the part not exceed 125 °C under worst case operating conditions verified in the end application. 4. I sat1: Peak current for approximately 20% rolloff @ +25 °C 5. I sat2: Peak current for approximately 20% rolloff @ +100 °C 6. I sat3: Peak current for approximately 20% rolloff @ +125 °C 7. K-factor: Used to determine B p-p for core loss (see graph). B p-p = K * L * ∆I * 10 -3 . B p-p:(Gauss), K: (K-factor from table), L: (Inductance in nH), ∆I (Peak to peak ripple current in Amps). 8. Part Number Definition: FP1008R7-Rxxx-R FP1008R7= Product code and size x= Version indicator Rxxx= Inductance value in μH, R= decimal point -R suffix = RoHS compliant Dimensions (mm) Part marking: FP1008R7, Rxxx (xxx=inductance value in uH, R=decimal point), xxxx=Lot code Tolerances are ±0.15 millimeters unless stated otherwise. All soldering surfaces to be coplanar within 0.1 millimeters Pad layout tolerances are ±0.1 millimeters unless stated otherwise DCR measured from point “a” to point “b” Do not route traces or vias underneath the inductor |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |